SAFETY LOCK-OUTS
The boiler’s electronic controller may activate the following safety lock-outs to stop the boiler functioning
in order to prevent serious damages. When any of these lock-outs occur, the boiler will switch off and an
alarm code will be displayed on boiler's screen.
IMPORTANT: If any of the safety lock-outs described below should occur repeatedly, switch
off the boiler and put in contact with the nearest official Technical Assistance
Service.
19.1
Temperature safety lock
When this lock-out occurs
"E-11"
alarm code (temperature alarm) will appear on the screen. The
burner will switch off and stop heating the installation.
This lock-out occurs when the temperature of boiler's water exceeds 110 ºC. To unlock it, wait until
the temperature drops below 100 ºC and press the button of the safety thermostat, located underside
of the electrical case of the boiler, after having removed the button cover: