Anchoring on the structure - Lifting unit attached on one side
129
999805802 - 03/2016
Gluing in the suspension point
In the case of large wall thicknesses or in corner and
end zones, a safe suspension point can be retrofitted
using 'Hilti HIT-RE 500-SD' adhesive or an equivalent
product.
Glue in a tie rod with Climbing cone SCP 20.0
b ... 215
mm
c ... diam. 95
mm
Comply with the manufacturer's installation
instructions for the adhesive!
A
Climbing cone SCP 20.0
B
Sealing sleeve SCP 20.0 (expendable anchoring component)
C
Tie rod 20.0mm (expendable anchoring component)
D
Adhesive: 'Hilti HIT-RE 500-SD' or equivalent product
E
Cone screw M36 SW50 9cm
☞
Important note:
For more information, please contact your Doka
technician.
c
b
98058-489-04
C
B
A
E
D