background image

Safe operation

To ensure safe and reliable operation of the devices, please observe
the following requirements:
Use the device only for its intended purpose;
Do not use devices that show signs of malfunctioning;
Avoid strong physical impacts on the device;
Protect devices and cables from contact with corrosive liquids;
Whenever a fault is detected in the device, please contact the manufacturer.

General information

RadioGate Plus series is an intelligent beDMX / Ethernet / DMX converter with merging functions 
that provides wireless data transmission according to the “beDMX” standard and is effective solution 
for controlling lighting equipment via DMX512 protocol. A special feature of the transceiver is its 
multifunctionality, which is expressed in the possibility various transformations, mergers (merging),
DMX512 protocols, RDM (ANSI E1.20), ArtNet (1,2,3,4), sACN (Draft, Release), KiNet (v1, v2), RTTrPL, 
data transmission of these protocols over a radio channel and through Ethernet network, with redundancy
functions, as well as the ability building different combinations of receiving / transmitting signals.
For data transmission over the radio channel, the transceiver uses the protocol "BeDMX", created on 
the basis of the Bluetooth 5.0 standard, which guarantees Reliable 2.4GHz wireless connection with 
the use of adaptive hopping functions and the presence of constant two-way communication between 
receiver and transmitter. Adaptive Frequency Hopping (AFH) helps to avoid disturbance from any other 
wireless equipment. To connect additional equipment and configure via Ethernet, the converter has 
a built-in Ethernet LAN 10/100Base-T port. Maximum distance is up to 1500 metres with directional
antennas. RadioGate Plus series is powered by AC ~90-250 V, 50/60 Hz or from Ethernet using the using 
the IEEE 802.3af standard – Power-over-Ethernet technology (depends on modification), or DC 12-24V.

Merging

HTP

: highest takes precedence

LTP

: latest takes precedence

AUTO:

 last modified takes precedence - intelligent merging mode

PRIORITY:

 for sACN streams with priority tag

BACKUP:

 primary/secondary universe backup

TRIGGER and X-FADE: 

dedicated channel / dedicated

universe controllable merging

3

RadioGate Plus

Warning!

The device uses hazardous
voltage AC 100-250V

Содержание RadioGate Plus

Страница 1: ...User Manual Version 1 05 April 5 2022 RadioGate Plus...

Страница 2: ...erging Connection types Installation Device configuration Wireless network configuring Switching device mode Operation Receiver mode Wireless status indication interface Troubleshooting Web settings M...

Страница 3: ...ability building different combinations of receiving transmitting signals For data transmission over the radio channel the transceiver uses the protocol BeDMX created on the basis of the Bluetooth 5...

Страница 4: ...ors 120 ohms on DMX bus In RadioGate Plus Arma DMX connection is made with terminal block connectors located inside the device case Ethernet connection The device connects to the network through RJ 45...

Страница 5: ...ct a wireless subnet using sections 3 and 4 DIP switches 4 For models set advanced device parameters using sections 7 and 8 of the DIP switch 5 Install the lid and tighten the screws Section 7 Subnet...

Страница 6: ...seconds during this process LEDs LINK green and STATUS red blink fast 4 Upon completion of search process verify the correctness of created network on the transmitter LEDs LINK green and STATUS red b...

Страница 7: ...ny of the settings have been saved When changes are saved the device applies the new settings immediately without having to power it down The status of each DMX port is indicated by the corresponding...

Страница 8: ...nfiguring the device Lack of voltage Network cable break Switch device function Device is not working no LED is on 8 RadioGate Plus LED LINK green LED STATUS red Status is on is off blinks slow is off...

Страница 9: ...Web settings RadioGate Plus devices support configuring most of their parameters through the web interface using HTTP protocol TCP port 80 9 RadioGate Plus...

Страница 10: ...rtNet 4 Ports Configuration and status of DMX ports Mode merging Pri unv protocol Pri unv number Sec unv protocol Sec unv number Status Port direction and merge mode for output Primary universe protoc...

Страница 11: ...onnected devices Refresh search list state detected devices RDM devices RDM devices list connected to DMX ports Advanced settings 11 RadioGate Plus To edit the advanced settings of the device click on...

Страница 12: ...larm sensor normally open closed Delay for triggering in milliseconds Current status of input open closed active alarm Save the current state of all DMX ports as scene to recall on trigger activation...

Страница 13: ...operate via the Internet is required Set the UDP port for ArtNet protocol Set the UDP port for sACN protocol Login and password for access to web interface of device If password is empty authentifica...

Страница 14: ...Device reboot button Current firmware name and version Select firmware file to upload to the device Upload the selected firmware file Firmware update 14 RadioGate Plus Warning To update firmware of t...

Страница 15: ...ormed by service personnel The device should be free from dirt dents connecting cables and wires must be intact and securely fastened Notes Please send all your warranty related questions to support s...

Страница 16: ...Sundrax Electronics 6008 First Central 200 2 Lakeside Drive Park Royal London NW10 7FQ United Kingdom 44 0 208 991 33 19 office sundrax com www sundrax com...

Отзывы: