background image

Switching device mode

for all modifications

1. Рower up the device. Depending on current settings saved in non-volatile memory, device starts
either in transmitter mode (green LED “LINK” is steady on or blinking), or in receiver mode (green LED
“LINK” is off).
2. If current mode is not correct for this device, switch the mode by pressing simultaneously 
and holding for 4 sec the “SETUP” and “RESET” buttons. The new mode is saved in non-volatile memory, 
and the device reboots with new settings. Configuration of the network, formed in transmitter mode, 
is preserved when the device is switched in receiver mode and back.
3. After setting the desired mode of operation, configure device in the receiver or transmitter mode
(see above).

Operation

RadioGate Plus devices start their normal operation in a few seconds after they have been powered up. 
Device always operates based on last saved settings. Viewing RadioGate Plus settings does not affect
normal operation until any of the settings have been saved. When changes are saved, the device applies 
the new settings immediately, without having to power it down. The status of each DMX port 
is indicated by the corresponding status LED.
In the input mode, port status LED is steady on if there is valid DMX input signal or flashes slowly
the DMX input signal is invalid or absent. In the output and loop modes, port status LED is steady
on when there is no data for output and blinks when new DMX data are transmitted (updated). 
In the off mode, port status LED is off. 
Current status of each port can be controlled through the web interface.

Receiver mode

1. When the power is turned on, the receiver waits for a connection request
from the transmitter. At the same time, the STATUS status LED (red) is constantly on.
2. When the connection to the transmitter is established, the communication LED
is constantly on LINK (green). DMX512 data received from the transmitter is output
to the output connector.
3. Pressing the RESET button (for DC version) disconnects the receiver from
the transmitter and rebooting the device. After rebooting, the receiver goes
into standby mode.

7

RadioGate Plus

Содержание RadioGate Plus

Страница 1: ...User Manual Version 1 05 April 5 2022 RadioGate Plus...

Страница 2: ...erging Connection types Installation Device configuration Wireless network configuring Switching device mode Operation Receiver mode Wireless status indication interface Troubleshooting Web settings M...

Страница 3: ...ability building different combinations of receiving transmitting signals For data transmission over the radio channel the transceiver uses the protocol BeDMX created on the basis of the Bluetooth 5...

Страница 4: ...ors 120 ohms on DMX bus In RadioGate Plus Arma DMX connection is made with terminal block connectors located inside the device case Ethernet connection The device connects to the network through RJ 45...

Страница 5: ...ct a wireless subnet using sections 3 and 4 DIP switches 4 For models set advanced device parameters using sections 7 and 8 of the DIP switch 5 Install the lid and tighten the screws Section 7 Subnet...

Страница 6: ...seconds during this process LEDs LINK green and STATUS red blink fast 4 Upon completion of search process verify the correctness of created network on the transmitter LEDs LINK green and STATUS red b...

Страница 7: ...ny of the settings have been saved When changes are saved the device applies the new settings immediately without having to power it down The status of each DMX port is indicated by the corresponding...

Страница 8: ...nfiguring the device Lack of voltage Network cable break Switch device function Device is not working no LED is on 8 RadioGate Plus LED LINK green LED STATUS red Status is on is off blinks slow is off...

Страница 9: ...Web settings RadioGate Plus devices support configuring most of their parameters through the web interface using HTTP protocol TCP port 80 9 RadioGate Plus...

Страница 10: ...rtNet 4 Ports Configuration and status of DMX ports Mode merging Pri unv protocol Pri unv number Sec unv protocol Sec unv number Status Port direction and merge mode for output Primary universe protoc...

Страница 11: ...onnected devices Refresh search list state detected devices RDM devices RDM devices list connected to DMX ports Advanced settings 11 RadioGate Plus To edit the advanced settings of the device click on...

Страница 12: ...larm sensor normally open closed Delay for triggering in milliseconds Current status of input open closed active alarm Save the current state of all DMX ports as scene to recall on trigger activation...

Страница 13: ...operate via the Internet is required Set the UDP port for ArtNet protocol Set the UDP port for sACN protocol Login and password for access to web interface of device If password is empty authentifica...

Страница 14: ...Device reboot button Current firmware name and version Select firmware file to upload to the device Upload the selected firmware file Firmware update 14 RadioGate Plus Warning To update firmware of t...

Страница 15: ...ormed by service personnel The device should be free from dirt dents connecting cables and wires must be intact and securely fastened Notes Please send all your warranty related questions to support s...

Страница 16: ...Sundrax Electronics 6008 First Central 200 2 Lakeside Drive Park Royal London NW10 7FQ United Kingdom 44 0 208 991 33 19 office sundrax com www sundrax com...

Отзывы: