Wireless status indication interface

Transmitter Mode

Receiver mode:

Normal operation, connected to transmitter.
Normal operation, no connection with transmitter.
Configuration mode, connected to transmitter being 
in the network configuration mode.
Off, non-functional or failure state.

Troubleshooting

The list of possible malfunctions and methods of their elimination

Method

eliminate

Manifestation

malfunctions

Probable

cause

Incorrect network configuration

Reconfigure the network according to the mode work

Connect the device to a working power outlet
Replace network cable

Invalid function devices

No connection single
transmitter or several
receivers

Wrong position Dip-switch mode

Invalid mode in saved device settings

Set DIP Switch Positions To 
with the item "Configuring the device"

Lack of voltage 
Network cable break 

Switch device function

Device is not working
no LED is on

8

RadioGate Plus

LED  “LINK”

(green)

LED  “STATUS”

(red)

Status

is on

is off

blinks slow

is off

 

Normal operation, all receivers are connected, valid
signal at the DMX-input.
Normal operation, all receivers are connected, no signal
at the DMX-input.

is on

is on

Normal operation, connection is being established with one
or more receivers or lost, or no receivers for connection, 
valid signal at the DMX-input.

blinks slow

blinks fast

is on

Normal operation, connection is being established with one
or more receivers or lost, or no receivers to connect
with no signal at the DMX-input.

blinks fast
blinks slow

Configuration mode, searching for receivers.
Configuration mode, new network configuration can be stored.

blinks slow
is off

is off

Off, non-functional or failure state.

LED “LINK”

(green)

LED “STATUS”

(red)

Status

is on

is off

is off

is on

 

is off

blinks slow

is off

is off

Содержание RadioGate Plus

Страница 1: ...User Manual Version 1 05 April 5 2022 RadioGate Plus...

Страница 2: ...erging Connection types Installation Device configuration Wireless network configuring Switching device mode Operation Receiver mode Wireless status indication interface Troubleshooting Web settings M...

Страница 3: ...ability building different combinations of receiving transmitting signals For data transmission over the radio channel the transceiver uses the protocol BeDMX created on the basis of the Bluetooth 5...

Страница 4: ...ors 120 ohms on DMX bus In RadioGate Plus Arma DMX connection is made with terminal block connectors located inside the device case Ethernet connection The device connects to the network through RJ 45...

Страница 5: ...ct a wireless subnet using sections 3 and 4 DIP switches 4 For models set advanced device parameters using sections 7 and 8 of the DIP switch 5 Install the lid and tighten the screws Section 7 Subnet...

Страница 6: ...seconds during this process LEDs LINK green and STATUS red blink fast 4 Upon completion of search process verify the correctness of created network on the transmitter LEDs LINK green and STATUS red b...

Страница 7: ...ny of the settings have been saved When changes are saved the device applies the new settings immediately without having to power it down The status of each DMX port is indicated by the corresponding...

Страница 8: ...nfiguring the device Lack of voltage Network cable break Switch device function Device is not working no LED is on 8 RadioGate Plus LED LINK green LED STATUS red Status is on is off blinks slow is off...

Страница 9: ...Web settings RadioGate Plus devices support configuring most of their parameters through the web interface using HTTP protocol TCP port 80 9 RadioGate Plus...

Страница 10: ...rtNet 4 Ports Configuration and status of DMX ports Mode merging Pri unv protocol Pri unv number Sec unv protocol Sec unv number Status Port direction and merge mode for output Primary universe protoc...

Страница 11: ...onnected devices Refresh search list state detected devices RDM devices RDM devices list connected to DMX ports Advanced settings 11 RadioGate Plus To edit the advanced settings of the device click on...

Страница 12: ...larm sensor normally open closed Delay for triggering in milliseconds Current status of input open closed active alarm Save the current state of all DMX ports as scene to recall on trigger activation...

Страница 13: ...operate via the Internet is required Set the UDP port for ArtNet protocol Set the UDP port for sACN protocol Login and password for access to web interface of device If password is empty authentifica...

Страница 14: ...Device reboot button Current firmware name and version Select firmware file to upload to the device Upload the selected firmware file Firmware update 14 RadioGate Plus Warning To update firmware of t...

Страница 15: ...ormed by service personnel The device should be free from dirt dents connecting cables and wires must be intact and securely fastened Notes Please send all your warranty related questions to support s...

Страница 16: ...Sundrax Electronics 6008 First Central 200 2 Lakeside Drive Park Royal London NW10 7FQ United Kingdom 44 0 208 991 33 19 office sundrax com www sundrax com...

Отзывы: