Parameter
Description
Navigation
Values
Default
Value
Push-button
code
It allows you to program a 4-digit code for
elevator car calls. A 4-digit code may be assigned
to each BCx elevator car button input,
corresponding to the elevator car pushbutton
inputs.
Example: if the BC0 pushbutton is associated
with the 0123 code, to reserv floor 0 from Cabin
you can:
a) keep pressed the floor 0 pushbutton for 3
seconds.
b) All COP pushbutton will blink
c) Press in sequence the pushbuttons
corresponding to the BC0, BC1, BC2, BC3;
Note: Enter a code between 0 and 9
corresponding to the inputs BC0 ÷ BC9
Programming Code “0 “ will enable the special
function Pent House
◄► (Select field)
▲▼ (Change value)
Controle
Temperature
ambient
Check the temperature in the engine room
through the sensor (if present). If the temperature
surpass the set thresholds for more than 30
seconds, the system stops at the floor and the
error is recorded. The control is only active during
normal operation or Cabin priority. After having
set the two thresholds, pressing Enter you can
perform the sensor calibration (immediately press
Enter to retain the current calibration, otherwise
set the room temperature value and then press
Enter). The first threshold can be set between -10
° C and +5 ° C while the second threshold can be
set b40 ° C and +75 ° C.
◄► (Select field)
▲▼ (Change value)
Without;
+5°C <=>
+40°C
Without
Automatic
Calls
When lift is in normal mode, “Automatic calls” can
be activated to perform a specific calls number
(up to 120 calls or unlimited) in steps of one
minute. However is possible to enable or not the
doors functionality (the system will also continue
to accept floor calls simulating programmed calls,
if enabled).
The function ends automatically when the
machineries are turned off or if the system is put
in inspection mode.
▲▼
(Increase/Decrease
◄► (Select doors)
0 <-> 120
∞
Yes - No
0
Yes
Monitor
UCM
A3 amendment.
Configure type of monitor.
For description, refer to
.
▲▼
(Increase/Decrease
◄► (Choice)
UCM
Installation type 81-1 / 81-20 / 81-21
Shaft access procedure and Protections.
For description, refer to
.
▲▼
(Increase/Decrease
◄► (Choice)