“Faults” Menu
This Menu lists the last 60 faults stored into the internal memory of the controller. All faults are described in the
WARNING: In case of black out, the internal memory is saved only if the battery is connected.
System Status
Description
Visualization
on
Serial display
High speed
The system is running in high speed mode
Low speed
The system is running in low speed mode
Door close
The door is completely closed
Door open
The door is opened (or opening/closing)
Car full load
The elevator car has been fully loaded
Photocell A
The input relevant to the photocell entrance A is active
Photocell B
The input relevant to the photocell entrance B is active
Light curtain A
The input relevant to the open door button of entrance A is active
Light curtain B
The input relevant to the open door button of entrance B is active
Floor 0 12:30:56
< Faults >
----- ENTER ---->
Floor 0
< Faults >
No faults
----- ENTER ---->
Floor 0
< Faults >
Faults: 4
Display ?
----- ENTER ----
>
< Faults > 3/4
43 = Inspection
Pos.: 0 # 1 Cod. 0
17/03/09 10:10 *
(see below for
details)
▲ ▼
Reset all recorded faults
(press ENTER to confirm)
NOTE: faults are deleted
when lift cabin stops
Floor 0
< Faults >
Faults: 4
Reset ?
▲ ▼
Clear the detected error on the limit
switch
(press ENTER to confirm)
NOTE: the actual cancellation occurs
only
in memory system is stopped
Floor 0
< Faults >
Faults: 4
Reset XXX? (see table
below)
Reference table
Fault
Description