Annex 10 – Shaft Protection
Annex 11 – Fire operation programming procedure
UCM
Installation Type
Reduced
Door Contacts
44
1,5 s
EN 81.20 / 21 with monostable contacts
Protection Device AMI 100 CMF
X
X
45
1,5 s
EN 81.20 / 21 with monostable contacts
Protection Device AMI 100 CMF
X
X(*)
46
1,5 s
EN 81.20 / 21 with monostable contacts
Protection Device AMI 100 CMF
X
X
X
X(*) = Means that contact is needed only at the lowest floor door.
The following table indicates how to set the Shaft Protection parameter according to the system. The parameter
activates two different functions:
• Checking jumpers on door contacts (SCS error)
• Unauthorized access control in the compartment (UAS error): function required on the Russian market.
Shaft Protection
SCS Fault
UAS Fault
Type
Door contacts
Hatch contacts
No
Disabled
Disabled
1 ... 5
Do not use
6
Yes
Disabled
7
Yes
Door contact N.O.
Disabled
8
Yes
Door contact N.C.
Disabled
9
Disabled
Disabled
Door contact N.O.
10
Disabled
Disabled
Door contact N.C.
11
Disabled
Door contact N.O.
Door contact N.O.
12
Disabled
Door contact N.C.
Door contact N.C.
13 ... 16
Do not use
17
Yes
Disabled
Door contact N.O.
18
Yes
Disabled
Door contact N.C.
19
Yes
Door contact N.O.
Door contact N.O.
20
Yes
Door contact N.C.
Door contact N.C.
Shaft Protection
Situation 1 – One Firefighters key only (at floor)