COIN / CURRENCY
SYMPTOM
POSSIBLE CAUSE
THINGS TO CHECK
WHAT TO DO
Will not accept
Coin return lever stuck.
Make sure changer &
Reposition or adjust changer
coins.
lever are mounted properly.
or lever as needed.
Power supply to vender.
Check for power at outlet.
Supply power to outlet.
Check outlet circuit breaker
Replace fuse or turn
or fuse.
circuit breaker on.
Power supply to cabinet
Check power going to
Repair or replace damaged
control board.
transformer.
or bad parts.
Check power going from
Repair or replace damaged
transformer to board.
or bad parts.
Check 1.6 Amp primary power
Replace fuse if bad.
fuse.
Coin mech interface
Check harness is plugged in.
Plug in harness.
harness to door control
board.
Check harness for backed out
Repair or replace damaged
or cut wires.
or bad parts.
Check harnessing from door
Repair or replace damaged
control board to cabinet
or bad parts.
control board.
Changer.
Acceptor dirty or foreign
Clean or replace acceptor.
matter in coin path.
Check changer operation
Replace changer with known
in diagnostics.
good changer.
Cabinet Control Board.
Check harnessing to and from
Repair or replace damaged or
cabinet control board.
bad parts.
Replace cabinet control board.
Accepts coins
Coin mech interface
Check harness for backed out
Repair or replace damaged or
but will not
harness to door control
or cut wires.
bad parts.
vend.
board.
Check harness from door
Repair or replace damaged or
control board to cabinet control
bad parts.
board.
Changer.
Check changer operation in
Replace changer with known
diagnostics
good changer.
Cabinet Control Board.
Check harnessing to & from
Repair or replace damaged or
cabinet control board.
bad parts.
Replace cabinet control board.
Changer will not
Coin mech interface
Check harness for backed out
Repair or replace damaged or
pay out coins.
harness to door control
or cut wires.
bad parts.
board.
Check harness from door
Repair or replace damaged or
control board to cabinet
bad parts.
control board.
Changer.
Check changer operation
Replace changer with known
in diagnostics.
good changer.
Cabinet Control Board.
Check harnessing to and from
Repair or replace damaged or
cabinet control board.
bad parts.
Replace cabinet control board.
Page 26
Содержание FLEXPAK 3000 DMV 72N
Страница 19: ...19 Press hold select buttons 1 2 simultaneously to move to next item on menu...
Страница 41: ......
Страница 48: ......
Страница 52: ......
Страница 56: ......