36
Symptom:
PRODUCT COLD BUT NOT COLD ENOUGH
Possible Cause:
Compressor runs but won't cool product.
WHAT TO CHECK
SOLUTION
1. Is the temperature control knob set properly?
2. Domestically, is the voltage supply between 103V and 127V?
3. Is the temperature control probe located properly?
4. Is the condenser clear of obstruction?
5. Is the evaporator fan free of obstruction?
6. Is the condenser fan free of obstruction?
7. Is the evaporator free of ice?
8. Is the temperature control operational?
9. Is the evaporator fan operational?
10. Is the condenser fan motor operational?
11. Is the refrigerant tubing free of kinks?
12. Is the overload operational?
13. Is the start relay operational?
14. Is there refrigerant in the system?
15. If all of the above steps fail....
1. YES,
see step 2.
NO,
set properly.
2. YES,
see step 3.
NO,
call power company.
3. YES,
see step 4.
NO,
correct.
4. YES,
see step 5.
NO,
clear, clean, or space the vender.
5. YES,
see step 6.
NO,
free any obstruction or replace.
6. YES,
see step 7.
NO,
free any obstruction or replace.
7. YES,
see step 8.
NO,
defrost & check the following: gasket seal,
port door seal, refrigerant charge.
.
8. YES,
see step 9.
NO,
replace.
9. YES,
see step 10.
NO,
replace.
10. YES,
see step 11.
NO,
replace.
11. YES,
see step 12.
NO,
repair or replace.
12. YES,
see step 13.
NO,
replace.
13. YES,
see step 14.
NO,
replace.
14. YES,
see step 15.
NO,
charge system and check for leaks.
15. Consult the Dixie-Narco Factory Service.
1-800-688-9090.
Note: Have the vender model and serial
number available.