Symptom:
NOISY REFRIGERATION UNIT
POSSIBLE CAUSES
SOLUTION
1. Are refrigerant lines free of contact with surfaces?
2. Is the condenser fan blade obstructed or damaged?
3. Is the evaporator fan blade obstructed or damaged?
4. Is compressor noisy?
5. If all of the above steps fail....
1. YES,
see step 2.
NO,
correct.
2. NO,
see step 3.
YES,
free any obstructions or replace the blade if
needed.
3. NO,
see step 4.
YES,
free any obstructions or replace the blade if
needed.
4. NO,
see step 5.
YES,
replace.
5. Consult the Dixie-Narco Factory Service
1-800-688-9090.
Note: Have the vender Model & Serial number
available..