IC100CX
1592022550
Quick reference guide IC100CX GB rel.1.0 03/03/2008 Page 36 di 39
DF01
Defrost control
0= No
1= Yes
0
1
DF02
Defrost type
0= Temperature / pressure
1= Time
2= External contact
0
2
DF03
Temperature / pressure Setpoint for starting the defrost
cycle
-50.0
-58
0.0
0
110
230
50
725
°C
°F
Bar
Psi
Decimal
integer
Decimal
integer
DF04
Temperature / pressure Setpoint for stopping the defrost
cycle
-50.0
-58
0.0
0
110
230
50
725
°C
°F
Bar
Psi
Decimal
integer
Decimal
integer
DF05
Minimum delay time before starting a forced defrost cycle
0
250
Sec
DF06
Minimum defrost duration
0
250
Sec
DF07
Maximum defrost duration
0
250
Min
DF08
Compressor Off time before starting a defrost cycle
0
250
Sec
DF09
Compressor Off time after a defrost cycle
0
250
Sec
DF10
Interval time between defrost cycles
0
99
MIN
DF11
Temperature setpoint to start a combined defrost cycle after
the DF10 counting time
-50.0
-58
110
230
°C
°F
Decimal
integer
DF12
Temperature Setpoint to stop a combined defrost
-50.0
-58
110
230
°C
°F
Decimal
integer
DF13
Forced activation of the 2
nd
compressor in defrost
0= Not enabled
1= Enabled
0
1
DF14
Forced fan activation during defrost and draining times
0= Not enabled
1= Enabled only for defrost
2= Enabled for defrost and draining time (dF09)
0
2
DF15
Temperature/Pressure Setpoint to start a forced condensing
fan control in defrost cycle
-50.0
-58
0.0
0
110
230
50
725
°C
°F
Bar
Psi
Decimal
integer
Decimal
integer
DF16
Low alarm control during defrost
0= Not enabled
1= Enabled
0
1
DF17
Low alarm delay time after changing the status of the 4-
ways valve
0
250
Sec
DF18
4-ways reversing valve
0= ON in cooling
1= ON in heating
0
1
DF19
Temperature/pressure Setpoint to start a forced defrost
cycle
-50.0
-58
0.0
0
110
230
50
725
°C
°F
bar
psi
Decimal
integer
Decimal
integer
DF20
Forced defrost cycle differential
0
0
25.0
45
°C
°F
Decimal
integer
Pr2
Password
0
999
Alarm Parameter