6.2 ADVANCED MENU
The advanced menu allows you to modify the position of the limit switches which have previously been set
and modify the set default parameters.
To access the Advanced Menu:
- STOP the door
- Set DIP 2 to ON
“ENCODER CALIB.”, the first item in the advanced menu, will appear on the display.
1 2 3 4 5 6 7 8
ON
ONCE PROGRAMMING HAS ENDED, SET DIP2 TO OFF
STEP 1
st
level options
2
nd
level options
Notes
1
Encoder Calibration
by scrolling
or
to confirm
Closed position
The door will move to the desired position in
man present mode and at low speed. All the
positions (closing, partial opening, opening)
must be set.
2
Photocell excluded
(step present only for
Reset doors)
by scrolling
or
to confirm
Change value
(1 unit
≅
3mm)
By increasing the value, the position of the
photocell by-pass is raised
3
Primary safety device
excluded
by scrolling
or
to confirm
Change value
(1 unit
≅
3mm)
By increasing the value, the position of the
primary safety by-pass is raised
4
Automatic closing
(default SI with T= 5 s)
by scrolling
or
to confirm
YES
NO
5
Automatic closing time
by scrolling
or
to confirm
Time variant
Option available only if YES has been
selected for point 4).
Value ranging from 0 to 100 sec.
6
Command mode
by scrolling
or
to confirm
Impulsivo
Selecting 1-9: if 1-9 is closed, the command
mode will be impulsive, if 1-9 is open the
command mode will be “dead man”
Uomo Presente
INPUT 1-9
7
Opening safety device
by scrolling
or
to confirm
YES
If set to YES, the closed door that receives
an opening command does not open if the
photocell is activated.
NO
8
Interlock
by scrolling
or
to confirm
NO INTERLOCK
AIRLOCK: door 2 opens with external
command only if door 1 is closed.
INTERLOCK: door 2 opens automatically
when door 1 has closed
AIRLOCK
INTERLOCK
9
Pre-flashing when
opening
(default no)
by scrolling
or
to confirm
YES
Pre-flashing has a set time of
3 sec.
NO
Remove cables from PIN 3, 4, 20 during programming
EN
Содержание 0DT869
Страница 20: ...20 0DT869 2019 01 30 INSTRUCTIONS POUR RESTAURATION TABLIER AVEC ISSUE DE SECOURS 3 5 1 1 4 2 STOP 6 A B C 1 m...
Страница 22: ...22 0DT869 2019 01 30...
Страница 24: ...DESSINS INSTALLATION M CANIQUE X Y 4 D C 3...
Страница 25: ...MECHANICAL INSTALLATION DRAWINGS 90 9 STOP C NO DS V W U M4x8 7 5 6 E F...
Страница 26: ...DESSINS INSTALLATION M CANIQUE H G L N N O N M I 1 2 8 9A 9B 11 10 INOX 4 8 x 13 GALVA 6 3 x 19...
Страница 27: ...27 0DT869 2019 01 30...
Страница 46: ...46 0DT869 2019 01 30 3 5 1 1 4 2 STOP 6 A B C 1 m EMERGENCY EXIT RESTORE CURTAIN INSTRUCTION...
Страница 48: ...Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www ditecentrematic com 0DT869FREN 2019 01 30...