- 40 -
0DT869 2019-01-30
7. ADJUSTING AND STARTING
7.1 Adjustment of the Safety Linear Encoder (SLE)
Trimmer
Description
R1
Adjustment of reaction sensitivity
(default on minimum)
LED
ON / Flashing
OFF
PWR
Power supply on
Power supply off
SA
• Initialisation
• Intervention due to obstacle
• Test running
• Test failed / alarm
Normal operating
no obstacle.
Dip-
switches
Description
OFF
ON
DIP 1
Control panel type
48E / 52E
/
DIP 2
Obstacle detected
after FC closing
limit switch
Disabled
Enabled (only
control panels
with INVERTER)
DIP 3
Scale of sensitivity
HIGH
(doors close
quickly)
LOW
(doors close
slowly)
DIP 4
Limit switch
polarity
0 = Limit switch
common 48E
1 = Limit switch
common 52E)
MAX
MIN
SLE