I

NSTALLATION

 M

ANUAL

 

Содержание I

Страница 1: ...I NSTALLATION M ANUAL ...

Страница 2: ... Control Page 14 Selecting the Delay Functions Page 14 Describing the Output Connections Page 15 MAG Lock Solenoid Page 15 Alarm Page 15 24 VAC Auxiliary Power Page 15 Connecting the Accessories Page 16 Description of Inputs Page 17 Receiver Connections Page 18 Gate Travel Distance Setting the Limit Switches Page 18 Emergency Releases Page 18 2002 Eagle Access Control Systems Inc All rights reserv...

Страница 3: ...ized use 6 All warning signs and placards must be installed where visible in the area of the gate 7 For a gate operator utilizing a non contact sensor such as a photo beam See instructions on the placement of non contact sensor for each type of application Care shall be given to reduce the risk of nuisance tripping such as when a vehicle trips the sensor while the gate is still moving One or more ...

Страница 4: ...ular entrance or exit to a drive parking lot or the like UL Listings __________________________________________ Gate A moving barrier such as a swinging sliding raising lowering rolling or like barrier that is a stand alone passage barrier or is that portion of a wall or fence system that controls entrance and or egress by persons or vehicles and completes the perimeter of a defined area _________...

Страница 5: ...any improper installation procedures caused by installer or user failing to comply with local building codes CAUTION ____________________ Precautions Be sure to mount ALL operating devices clearly out of reach of through gate ____________________ Regarding Ornamental Grill Styled Gates Injuries may be avoided if a mesh or screen is installed on the gate Injuries resulting from hands and feet becom...

Страница 6: ... of 4 Four inches between the rollers as shown in Example B Also when fully open the end of the sliding gate must stop at least 3 three inches from any wall or other objects as shown in Example C CAUTION For safety reasons a positive stop must be installed on the gate track prior to installation of the gate This will assure that the gate does not exceed movement limit and derail while opening or c...

Страница 7: ...om 7 CAUTION The No Weld Chain Kit comes standard with all sliding gate units Kit Recommended Positive Stop Locations CORRECT Minimum space between gate and output sprocket must be 4 After you position the gate operator bolt down the operator to the concrete bed Make certain the concrete bed is solid ____________________ ____________________ EAGLE Rear Chain Installation For Rear Installations be ...

Страница 8: ...estions only Please consult local codes for actual requirements in your area Note ____________________ Selecting Opening Direction of Gate Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com 8 5 18 18 R E D H E A D F A S T E N E R 1 2 x 3 1 2 Recommended Dimensions Concrete Pad Diagram N T S 18 FEATURE SELECTOR To select the opening direction of the gate use the Feature Selector a...

Страница 9: ... prevent the gate from closing on a vehicle while it is exiting or stopped in the middle of the gate area The purpose of the exit loop is to automatically open the gate when a vehicle approaches to exit Exit Loop Operation Wires must be wrapped inside the groove three times Once you have completed the process fill up the grooves with a proper seal Eagle Access Control Systems Inc 800 708 8848 www ...

Страница 10: ...PORTANT When Adjusting Sensors Remember The level of sensitivity depends on the weight of the gate and the conditions of installation TWISTED GROUND WIRES REVERSE LOOP REVERSE LOOP EXIT LOOP A B LOOP DETECTOR LOOP HARNESS ____________________ Connecting the Loop Detector See larger Exit Loop Detail on Page 9 For 110V power connect to the 100 junction power box For 24V AC power connect to terminal ...

Страница 11: ...lation settings The switch description is as follows Note The power should always be turned off when designating feature selector switches The reset button is used to reset the micropressor IF YOU MAKE A CHANGE WITH THE SWITCHES YOU MUST USE THE RESET BUTTON TO APPLY CHANGES Note If the power light is on and the operator does not function press the reset button once If this does not solve the prob...

Страница 12: ...Slave Operations Master Control Options Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com 12 EAGLE EAGLE NOTE If the Master and Slave Operators are not communicating properly verify if they are on the same phase by switching the phase jumper on either the master or the Slave Unit Master and Slave Operation ____________________ Set dip switch 1 ON for the Master Set dip switch 1 ...

Страница 13: ...e Control Options Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com 13 Switch 1 must be set to the Slave or to the off position Switch 2 must be set to the open left or to the open right position Switch 3 brake on off Switch 4 Not in use ...

Страница 14: ...can be used for loop detectors and receivers Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com 14 Safety Alarm If the gate hits an obstruction twice while closing or opening the system will shut down for 5 minutes On the Board you have two options of reset mode Selecting the off position will require a manual reset of the board if the previous happens However by selecting the On...

Страница 15: ...e exeption of the MAG Lock all of these accessories can be installed on the Master or Slave operator Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com 15 Reverse Loop Photo Eye Phantom Loop Exit Loop Key Lock Box Fire Lock Box MAG Lock Phone Entry System Edge Sensor ...

Страница 16: ... active when the gate is opening and or closing Multiple devices may be connected in parallel to the Edge Sensor Input Phantom Loop Momentary or Continuous Signal This input is active only when the gate is at rest in the fully open position The input has no effect on the gate when fully closed or while closing or opening Continuous activation will prevent the gate from moving in the close directio...

Страница 17: ...Wire Connections 3 Wire Connections The Receiver Terminal is mounted on the control box for easy installation and is pre wired for a 3 wire or 4 wire receiver ____________________ Adjust cams for proper stoppage Be sure that the locking plate is locked into place after each adjustment Limit Switches Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com 17 Limit Switches 24V COMMON G...

Страница 18: ...not require a crank or special tool to manually open the gate in case of emergency If a situation does arrise simply turn off the power switch and push open the gate Mounting The Secondary Entrapment Note Eagle Access Control Systems Inc recommends the installation of Edge Sensors on all sliding gate operator systems Edge Sensors should be appropriately installed at recommended locations to ensure...

Страница 19: ...Eagle Access Control Systems Inc 13286 Paxton Street Pacoima CA 91331 Tel 818 899 2777 Fax 818 899 2666 Toll Free 800 708 8848 www EagleOperators com ...