28
Directed Digital System VW02
© 2016 Directed. All rights reserved.
LED diagnostics and troubleshooting
This section provides LED diagnostics and troubleshooting information to guide you through the various stages of
your installation.
Module programming – Firmware specific
LED
Description
Troubleshooting
Comment
Off
Module has no
power.
Make sure the D2D harness is connected or that
the 12 volt is present between the red and black
wires. If the 12 Volt is present, the module may be
defective.
Solid red
Module is powered.
Waiting to begin
the programming
sequence.
Verify your power lines
Normal operation.
Flashes green
CAN bus detected,
car detection in
progress.
Check the firmware name and version.
Normal operation.
Module programming – Error codes
LED
Description
Troubleshooting
Comment
Flashes red x 1
FT CAN not
detected.
Check CAN connection.
Flashes red x 2
HS CAN not
detected.
Flashes red x 3
Ignition not
detected.
Check the firmware name and version.
Flashes red x 4
VIN not detected.
Flashes red x 5
Internal error.
Report the error to tech support.
Shutdown codes
LED
Description
Troubleshooting
Comment
Flashes red x 1
Run safe shutdown.
Used to check the installation and for troubleshooting
purposes.
Used to check for internal safety operation.
Does not represent an error.
Flashes red x 2
Brake shutdown.
Active ground when running (status)
LED
Description
Troubleshooting
Comment
Flashes green
GWR (Status)
command received.
Used to ensure the module has received the remote
start message and has enabled the remote start
runtime.
Commands can come from RF, D2D or
W2W.
Содержание VW02
Страница 34: ...Directed Digital System VW02 2016 Directed All rights reserved Notes...
Страница 37: ...Directed Digital System VW02 2016 Directed All rights reserved Notes...
Страница 40: ...Directed Digital System VW02 2016 Directed All rights reserved Notes...
Страница 43: ...Directed Digital System VW02 2016 Directed All rights reserved Notes...