UltiMate 3000 Nano and Cap - System Installation and Application
5
VWD-3100—Variable wavelength detector for one wavelength
VWD-3400—Variable wavelength detector for four wavelengths
with nano flow cell (must be ordered separately)
5074.0005
5074.0010
6074.0270
FLM-3100(B) with two 10-port micro switching valves
Standard flow manager (FLM-3100)
Biocompatible flow manager (FLM-3100B)
—
or
—
FLM-3200(B) with 10-port micro and 6-port nano switching valves
Standard flow manager (FLM-3200)
Biocompatible flow manager (FLM-3200B)
—
or
—
FLM-3300(B) with one 10-port micro switching valve
Standard flow manager (FLM-3300)
Biocompatible flow manager (FLM-3300B)
5720.0015
5721.0015
5720.0025
5721.0025
5720.0035
5721.0035
Monolithic
HPLC
Note:
These flow managers are fitted with a splitter cartridge
for a split ratio of 1:100.
WPS-3000T(B)— Autosampler with temperature control
Standard autosampler (WPS-3000)T
Biocompatible autosampler (WPS-3000TB)
—
or
—
WPS-3000(B)— Autosampler without temperature control
Standard autosampler (WPS-3000)
Biocompatible autosampler (WPS-3000B)
5820.0010
5821.0010
5820.0020
5821.0020
1.5 Intended Use
The UltiMate 3000 system is designed to perform equally well as system for routine analyses
or as a sophisticated research instrument for use in capillary, nano, and micro HPLC (high
performance liquid chromatography) applications.
The system is controlled by the
Chromeleon
Chromatography Management System. However, it
can also be operated with other data systems, such as Analyst
®
(Applied Biosystems/MDS
Sciex), HyStar™ (Bruker Daltonics), or Xcalibur
®
(Thermo Electron Corporation). To do so,
installation of the DCMS
Link
(Dionex Chromatography Mass Spectrometry Link) software is
required.
Please note that the system may be operated only using the accessories originally supplied with
the system modules and within its technical specification (
→
If there is any question regarding appropriate usage, contact Dionex before proceeding.
Dionex cannot be held liable for any damage, material or otherwise, resulting from inappropriate
or improper use of the system.
Содержание UltiMate 3000
Страница 1: ...UltiMate 3000 Nano and Cap System Installation and Application Revision 1 0 Date May 2006 2006 Dionex...
Страница 2: ...UltiMate 3000 Nano and Cap System Installation and Application...
Страница 10: ...UltiMate 3000 Nano and Cap System Installation and Application 6...
Страница 60: ...UltiMate 3000 Nano and Cap System Installation and Application 56...
Страница 66: ...UltiMate 3000 Nano and Cap System Installation and Application 62...
Страница 72: ...UltiMate 3000 Nano and Cap System Installation and Application 68...