55
Optimized layout for A4 print.
USER_MAN_ENG_DGT1SX
LEGEND:
Indicates repeated pressing of
the key.
Parameter visible only
under certain conditions.
Parameter or menu subject
to approval.
Default value of the parameter.
Alarms
Alarm
Description
preC
Displayed if you try to calibrate a point without first confirming the number of calibration points (
n
tp
).
er.mot
Calibration error: unstable weight during point acquisition.
erpnt
Calibration error: during the acquisition of a calibration point a NULL value was read from the converter.
err.x.1
Error that occurs if the capacity of channel
X
is not set, or there is an error in the calibration parameters of
channel
X
, where
X
indicates the number of the channel to which the error refers.
over x
Error that occurs if the capacity of channel
X
is not set, or there is an error in the calibration parameters of
channel
X
, where
X
indicates the number of the channel to which the error refers.
er 11
Calibration error: a sample weight that is too low was used; it is recommended to use a weight of at least half
the scale’s capacity.
er 12
Calibration error: The acquired calibration point (
tp
1
/
tp
2
/
tp
3
) is equal to the zero point (
tp0
).
er 37
Scale to be calibrated (we recommend resetting the transmitter to the factory default “
defau
” settings before
proceeding).
er 39
Scale to be calibrated (we recommend resetting the transmitter to the factory default “
defau
” settings before
proceeding).
C.er. -36
Negative internal points were calculated during calibration:
•
the calibration point is below the zero point;
•
the signal is negative (check the connections).
C.er. -37
Internal points below the minimum value were calculated during calibration:
•
the calibration point is equal to the zero point;
•
too high a capacity has been set with respect to the division.
hw,err
Hardware error: software not compatible with the installed hardware.
al.err
Displayed when the alibi memory is enabled and the transmitter does not detect the presence of the card
when the power is turned on. The
Conv
function is set automatically, but not saved in the setup environment.
busy
Printing in progress (printer serial port busy) or transmitter waiting to transmit a print to PC.
unstab
You are trying to print with an unstable weight.
un.over
You are trying to print with the weight in underload / overload.
------
The weight is overloaded (9 divisions over the maximum capacity).
------
The weight is underloaded.
Approved transmitter: -100 divisions.
Non-approved transmitter: -maximum capacity -9 divisions.
Gros.er
You are trying to print with a non-positive gross weight (less than or equal to zero).
ner.err
You are trying to print with a non-positive net weight (less than or equal to zero).
no.0.uns
Weight not passed by net 0 or instability.
Conv
You are trying to print while the transmitter is converting the unit of measurement.
err,CLk
Communication problems with the clock card of the transmitter.
Cel.err
Signal anomaly: check the connection of the cells.
Содержание DGT1SX
Страница 1: ...www diniargeo com DGT1SX High speed digital weight transmitter ENGLISH USER MANUAL...
Страница 2: ......
Страница 6: ...6 Optimized layout for A4 print USER_MAN_ENG_DGT1SX...
Страница 57: ...57 Optimized layout for A4 print USER_MAN_ENG_DGT1SX Notes...
Страница 58: ...58 Optimized layout for A4 print USER_MAN_ENG_DGT1SX Notes...
Страница 59: ......