50
Optimized layout for A4 print.
USER_MAN_ENG_DGT1SX
Modbus Protocol
MODBUS REGISTERS FOR DATA READING (SINGLE SCALE)
Data
Register
DESCRIPTION
Gross Weight
30001
Gross weight value.
30002
Net Weight
30003
Net weight value.
30004
Input status
register
30005
Bit 15
(msb)
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
(lsb)
Active channel.
Active channel.
No function.
No function.
No function.
No function.
Input no. 2 status.
Input no. 1 status.
Bit 7
(msb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(lsb)
Gross zero zone (0 = “outside zone 0”; 1 = “in zone 0”).
Tare PT (1 = a preset tare is active).
Tare (1 = a tare is active).
Overload condition (0 = No; 1 = Overload).
Underload condition (0 = No; 1 = Underload).
Stability (0 = Unstable; 1 = Stable).
Gross weight sign (0 = “+”; 1 = “-”).
Net weight sign (0 = “+”; 1 = “-”).
Command status
register
30006
Last command received.
Bit 7
(msb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(lsb)
Last command result.
Last command result.
Last command result.
Last command result.
Processed command count.
Processed command count.
Processed command count.
Processed command count.
Output status
register
30007
No function.
Bit 7
(msb)
...
Bit 2
Bit 1
Bit 0
(lsb)
No function.
...
No function.
Digital output 1 status (0 = OFF; 1 = ON).
Digital output 2 status (0 = OFF; 1 = ON).
µV Channel 1
30111
µV value.
This manual contains the main registers for reading data / sending commands.
Refer to the Modbus protocol manual for a complete list of available registers.
Содержание DGT1SX
Страница 1: ...www diniargeo com DGT1SX High speed digital weight transmitter ENGLISH USER MANUAL...
Страница 2: ......
Страница 6: ...6 Optimized layout for A4 print USER_MAN_ENG_DGT1SX...
Страница 57: ...57 Optimized layout for A4 print USER_MAN_ENG_DGT1SX Notes...
Страница 58: ...58 Optimized layout for A4 print USER_MAN_ENG_DGT1SX Notes...
Страница 59: ......