Testing System Components
Requesting No
Test Summary
Display
If you answer 0 (no), a display similar to the following is shown
after a few minutes:
?06 HLT INST
PC=00003C17
PSL=00000000
>>>
This display tells you that the test has halted and the system
has returned you to the console prompt ( >>> ).
After Any
Testing
When you complete any diagnostic test, enter the UNJAM
command, as follows:
>>> U
Return
Resuming Normal Operation After Testing
Two Ways to
Reboot
While you are running any of the tests or procedures in this
chapter, you are in console mode. To resume normal operation
of the system, you must reenter program mode. There are two
ways to enter program mode:
1.
Enter BOOT at the console prompt (>>>) and press the
Return key. The system searches each device in turn for the
operating system software.
If you set the boot device using the SET BOOT command,
the system goes directly to the device set as the default boot
device.
2.
Enter BOOT followed by a space and one of the OpenVMS
device mnemonics listed in Table 5–5.
Testing System Components 5–15