![Digital Equipment StorageWorks RAID Array 410 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/digital-equipment/storageworks-raid-array-410/storageworks-raid-array-410_installation-manual_2498885062.webp)
Chapter 3. IBM AIX
EK–SM410–UP. A01
3–9
3.4
Recording Your Configuration Data
In the following steps, you need to record your configuration for use later in this
procedure.
First, record the configuration of the controller(s):
swxrc> show this_controller full
Fill in the controller configuration forms below (dual-redundant example shown):
Controller:
SWXRC-04 ZG43700116 Firmware V27Z-0, Hardware A02
Configured for dual-redundancy with ZG43700109
In dual-redundant configuration
SCSI address 7
Time: NOT SET
Host port:
SCSI target(s) ________ Preferred target(s) ________
Cache:
32 megabyte write cache, version 2
Cache is GOOD
Battery is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
CACHE_POLICY = _____
Host Functionality Mode = B
Licensing information:
RAID (RAID Option) is ENABLED, license key is VALID
WBCA (Writeback Cache Option) is ENABLED, license key is VALID
MIRR (Disk Mirroring Option) is ENABLED, license key is VALID
Extended information:
Terminal speed 9600 baud, eight bit, no parity, 1 stop bit
Operation control: 00000004 Security state code: 95018
Configuration backup disabled