![Digital Equipment StorageWorks RAID Array 410 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/digital-equipment/storageworks-raid-array-410/storageworks-raid-array-410_installation-manual_2498885033.webp)
Chapter 1. Digital Unix
EK–SM410–UP. A01
1–21
Duplicate this entry. Then replace all occurrences of "HSZ4" with "HSZ5" The
duplicate entry will then look like the one below. If you would prefer; you can
just type in the entry below but the cut/paste is easier and less prone to error.
/* HSZ50 */
{"DEC HSZ5", 12, DEV_HSZ50, (ALL_DTYPE_DIRECT << DTYPE_SHFT) | SZ_HARD_DISK
| SZ_RAID ,
(struct pt_info *)ccmn_hsx01_sizes, NULL, DEC_MAX_REC, NO_DENS_TAB,
NO_MODE_TAB,
(SZ_LONG_STO_RETRY | SZ_DYNAMIC_GEOM | SZ_DISPERSE_QUE | SZ_REORDER),
NO_OPT_CMDS, 90, 74, DD_REQSNS_VAL |
DD_INQ_VAL,
36, 160
},
7. Save and Exit the editor.
8.
cd /usr/include/io/common
9. cp devio.h devio.h.org
10. Using your favorite editor open the "devio.h" file for editing.
11. Locate the following line:
#define DEV_HSZ40 "HSZ40" /* SCSI multi-spindle RAID disk */
12. Copy the above line and change both HSZ40s to HSZ50s. The resulting line looks
like the one below.
#define DEV_HSZ50 "HSZ50" /* SCSI multi-spindle RAID disk */
13.
Save and Exit the editor.
14.
cd /sys/conf
15.
Rebuild your kernel using the "
doconfig -c {SYSTEM_NAME}
"
command. For more information consult the man page on "doconfig."
16.
Make a backup copy of your current kernel.
17.
The output of the
doconfig
indicates the location of the new kernel. Copy the
new kernel into the root directory.
18.
Re-boot your system.
1.12
Installing StorageWorks Software
To install the StorageWorks Software for Digital UNIX, follow the steps from the
Getting Started – RAID Array 450 V5.0 for Digital UNIX.
1.13
Congratulations
This completes the RAID Array 450 Upgrade Procedure. The system should be ready to
place on-line. If you cannot activate your system, specific troubleshooting or data