Chapter 6. NetWare–PCI
EK–SM410–UP. A01
6–13
3. Connect a maintenance terminal to the maintenance port of the new controller as
shown in Figure 6–6.
Figure 6
−−
6 Making a Serial Connection to the HSZ50 Controller
4. Insert the new program card with HSOF Version 5.0 into the new controller. The
program card eject button extends when the card is fully inserted.
5. Snap the ESD shield into place over the program card.
6. Power ON the entire subsystem.
7. If the controller initializes correctly, its green reset LED begins to flash once per
second. If an error occurs during initialization, the OCP displays a code. If necessary,
refer to Chapter 1, Troubleshooting in the Servicing your StorageWorks Subsystem,
HSZ50 Array Controller, HSOF Version 5.0 to analyze the code.
6.8
Establishing Connection with a Maintenance Terminal
To establish a connection between you PC and controller, you must use a
communications program. Follow these steps to make the connection:
1. Start a communication program on your PC.
2. Set the communications program to use the serial port that is connected to the
controller.
3. Set the terminal communications parameters to:
•
9600 Baud
•
8-bits
•
1 stop bit
•
No parity
After connecting the maintenance terminal cable to the controller, press the Enter key.
The CLI prompt appears in the window similar to the following:
HSZ>