![Digital Equipment PRIORIS ZX Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/digital-equipment/prioris-zx/prioris-zx_service-maintenance-manual_2498874061.webp)
Digital PRIORIS ZX Server
Service Procedures
MCS Logistics Engineering - Nijmegen
65
Single Channel SCSI Configuration
To connect SCSI devices to a single SCSI channel, perform the following:
1) Connect the SCSI cables as shown in Figure 3-22.
2) If using top 5¼-inch drive bay, connect appropriate power cable to device.
3) Replace and lock side panels.
4) Connect external devices and restore power.
5) Run SCSI
Select
to configure the server.
Refer to
Chapter 2, “Server Utilities & Configuration”
and to the SCSI documentation for
additional configuration information.
NOTE
Server’s with this configuration are shipped with an additional terminator to enable to
split the storage backplane
Legend
Component
A
Adaptec 7870 narrow/wide SCSI connector (SCSI bus A)
B
68-pin-to-50-pin adapter cable to CD-ROM drive
C
68-pin-to-50-pin adapter cable to top-right drive bay
D
Backplane, 68-pin connector
E
Terminator
(1)
F
Jumper cable
G
External SCSI connector
(1)
This terminator might be removed and replaced with a 68-pin wide cable to connect to an external SCSI device.
Figure 3 - 22 Single Channel SCSI
Configuration
DEC00733-2
E
D
C
B
F
A
G