![Digital Equipment PRIORIS ZX Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/digital-equipment/prioris-zx/prioris-zx_service-maintenance-manual_2498874052.webp)
Service Procedures
Digital PRIORIS ZX Server
56
MCS Logistics Engineering - Nijmegen
Upgrade Procedures
Upgrading the CPU Module Configuration
The Prioris ZX 5000 MP Series Server one or two (1P, 2P) processor configurations include a single CPU
module. The Prioris ZX 5000 MP Series Server three or four (3P, 4P) processor configurations include
two CPU modules.
The following procedure can be used to upgrade 1P or 2P CPU modules to 3P or 4P CPU modules:
1) Turn off the server.
2) Disconnect external devices, ac power, and monitor power.
3) Unlock and remove left side panel.
4) Install the new CPU module and secure with retaining bracket in CPU slot 2.
5) Replace and lock left side panel.
6) Connect external devices and restore power.
7) Run the SCU to configure the server for the new CPU module(s).
Refer to
Chapter 2, “Server Utilities & Configuration”
for information on running the SCU
See pevious section supported CPU configurations.
NOTE
The server will not power up with the side panel removed.
Figure 3 - 17 Installing a
CPU Module