6: Troubleshooting
Colorwriter LSR 2000 Printer
Service Guide
6-41
Table 6-23
E004 Fixing failure (Heater wire breakage)
Cause
Step
Check
Decision
Action
Fixing upper heater
Thermoswitch
1
Turn the power switch OFF,
and remove the fixing unit. Is
there continuity between fixing
unit connectors J21-1 and
J21-2?
NO
Check the continuity of
the fixing upper heater
and the thermoswitch,
and replace defective
parts.
Fixing lower heater
Thermoswitch
2
Is there continuity between
fixing unit connectors J21-3
and J21-4 when the fixing unit
is removed?
NO
Check the continuity of
the fixing lower heater
and the thermoswitch,
and replace defective
parts.
Power supply unit
3
Does it improve when you
replace the power supply unit?
YES
Replace the power
supply unit.
DC controller PCB
Mechanical controller PCB
NO
Replace and check as
follows:
• DC controller PCB
• Mechanical
controller PCB
Table 6-24
E006 Oil overflow failure
Cause
Step
Check
Decision
Action
Poor connection
1
Are oil overflow sensor
connector J29, fixing unit
connector J21 and mechanical
controller PCB connector
J2009 connections good?
NO
Reconnect them.
Fixing unit oil supply route
2
Is trash stopping up the hose
between the oil catch tray and
the oil pump?
YES
Remove the trash or
replace the parts.
Fixing unit
3
Does it improve when you
replace the fixing unit?
YES
Replace the fixing unit.
Mechanical controller PCB
DC controller PCB
NO
Replace and check as
follows:
• Mechanical
controller PCB
• DC controller PCB