6: Troubleshooting Procedures
6-20
Colorwriter LSR 2000 Printer
Service Guide
To adjust manual feeding tray side registration
This adjustment can be performed using either the Density Control
Panel or the printer driver tester.
The procedure for using the printer driver tester is described below.
Refer to “Using the density control panel” on page 2-1 for the
procedure using the Density Control Panel.
1. After connecting the printer driver tester to the printer, turn
the printer power switch ON while holding down the TEST PRINT
key on the Density Control Panel.
2. Press the ADJUSTMENT key to select the ADJUSTMENT mode.
3. Press the MANUAL key to select the MANUAL mode. Then input
keys in the following order:
•
WRITE key
•
Input
AA02
by the NUMERAL keys.
•
BIT key
•
Input the adjustment numerical value by the NUMERAL keys.
05-35 (0.5mm-3.5mm)
•
ENTER key
AAAA will appear on the display unit if the data are being
written, and FFFF if they are not being written.
If you strike a key by mistake, press the CANCEL key.
To adjust cassette side registration
This adjustment can be performed by using either the Density
Control Panel or the printer driver tester.
The procedure using the printer driver tester is described below.
Refer to “Using the density control panel” on page 2-1 for the
procedure using the Density Control Panel.
1. After connecting the printer driver tester to the printer, turn
the printer power switch ON while holding down the TEST PRINT
key on the Density Control Panel.
2. Press the ADJUSTMENT key to select the ADJUSTMENT mode.
3. Press the MANUAL key to select the MANUAL mode. Then input
keys in the following order:
•
WRITE key
•
Input
AA03
by the NUMERAL keys.
•
BIT key