3: Operation
Colorwriter LSR 2000 Printer
Service Guide
3-69
Figure 3-53
Developing unit motor drive circuit
Image quality stability control
The printer is protected by image quality stability control to
minimize fluctuations in image density due to environmental
changes, deterioration of the photosensitive drum and toner.
Environment-change correction control
The printer has a temperature/humidity sensor PCB installed under
the ejection unit. The DC controller monitors the
thermal/humidity sensors to control temperature and humidity
within the printer. This allows the printer to obtain optimum image
quality.
Environment-change correction control controls the following
high-voltage values:
•
Primary charging voltage
•
Transfer bias
•
Attraction bias
•
Discharge AC bias
•
ON/OFF of the separation charging unit
Maximum density control
Maximum density control is performed to stabilize the maximum
density for each color. This determines an optimum developing
bias.
Mechanical controller PCB
M3
J2016-1
-2
-8
-4
-5
-6
+24VC
DEVPHA
/DEVPHA
DEVPHB
/DEVPHB
DEVICH
+5V
AO
/AO
BO
/BO
COMA
COMB
53
60
59
58
57
Developing motor
12
8
1
11
18
7
14
6
5
16
17
3
(Q2003)
(Q2001)
CPU
Developing