5: Service Procedures
5-18
Manual: Colorwriter LSR 2000 Service Guide
Draft:
Last Modified: January 20, 1996 5:36 pm
File: Service-externals
Page: 5-18
Colorwriter LSR 2000 Printer
Service Guide
3. Remove the screws and the display panel.
Density Control Panel
To remove the Density Control Panel
1. Remove the rear cover.
2. Remove the nine screws and the shield plate.
3. Remove the screw and the fan cover.
➁
➀
1—Screws
2—Display panel
➁
➀
1—Screw
2—Fan cover
5: Service Procedures
Colorwriter LSR 2000 Printer
Service Guide
5-19
Manual: Colorwriter LSR 2000 Service Guide
Draft:
Last Modified: January 20, 1996 5:36 pm
File: Service-externals
Page: 5-19
4. Remove the two screws and disconnect the connector
to remove the Density Control Panel.
Exhaust Fan
The three fan motors installed in this printer work to
prevent a rise in the internal temperature. The role of
each fan is as follows:
• Fixing unit fan (FM1)—Blows air from around the
fixing unit out of the printer.
• Electrical unit fan (FM2)—Blows air from around the
various PCBs and the laser/scanner unit out of the
printer.
➀
➂
➁
1—Screws
3—Density Control Panel
2—Connector