DEPOSIT
Address
Address is a longword address that specifies the first location
into which data is deposited.
Data
Data is the data to be deposited. If the specified data is larger
than the deposit data size, then the console ignores the command
and issues an error response. If the specified data is smaller
than the deposit data size, then it is extended on the left with 0s.
Examples
The next example deposits 01234567 into location 00400000 and
five subsequent locations:
>>> D -PM -N:5 400000 01234567
Return
To verify that the deposit worked properly, enter the following:
>>> E -PM -N:5 400000
Return
Result:
PMEM: 00000000.00400000 01234567
PMEM: 00000000.00400004 01234567
PMEM: 00000000.00400008 01234567
PMEM: 00000000.0040000C 01234567
PMEM: 00000000.00400010 01234567
PMEM: 00000000.00400014 01234567
>>>
The next example deposits 0123456789ABCDEF into general
purpose registers 00 through 31 inclusive:
>>> D -R -N:1F 0 0123456789ABCDEF
Return
To verify that the deposit was successful, enter the following:
>>> E -R -N:1F 0
Return
Result:
13–8
Содержание DEC 3000 600 AXP
Страница 57: ...BA47X AA Vertical Floor Stand Figure 3 8 Removing the Mounting Plate MLO 011165 4 5 3 12...
Страница 60: ...System Cover Figure 3 9 Removing the System Cover MLO 008608 2 2 1 0 1 3 15...
Страница 65: ...Removable Media Devices Figure 3 11 Loosening the Screws on the Bracket MLO 011167 1 3 20...
Страница 81: ...I O Board Figure 3 18 Removing the I O Board 1 2 3 3 4 MLO 011172 3 36...
Страница 149: ...Front View Figure 6 1 Front View Line In 1 2 3 4 5 MLO 007553 7 8 9 10 11 12 6 14 13 6 6...
Страница 152: ...Rear View Figure 6 2 Rear View ISDN S3 1 3 4 5 6 8 10 11 MLO 010854 2 1 0 3 4 5 2 7 9 6 9...
Страница 189: ...Power Supply Figure 8 10 Removing the Power Supply MLO 011224 3 4 2 8 20...
Страница 193: ...RZxx Disk Drives Figure 8 11 Removing an RZxx Drive 1 2 4 3 MLO 011225 8 24...
Страница 199: ...I O Module Figure 8 14 I O Module Cable Connections 2 1 0 MLO 011227 ISDN S3 3 4 5 1 8 30...
Страница 200: ...I O Module Figure 8 15 Removing the I O Module Side View MLO 011228 2 3 4 5 6 8 31...
Страница 204: ...Fans Figure 8 17 Removing a Fan 1 Front 2 3 4 MLO 011229 8 35...
Страница 207: ...Memory Mother Board Figure 8 18 Removing a Memory Mother Board MLO 011230 1 2 8 38...
Страница 210: ...Memory Module Figure 8 19 Removing SIMMs 1 2 MLO 011231 8 41...
Страница 291: ...Installation Procedure Figure 11 14 Front View of the System Line In 1 2 3 4 5 6 7 8 9 10 11 MLO 011260 11 27...
Страница 319: ...Installation Procedure Figure 12 14 Front View of the System Line In 1 2 11 10 9 8 7 6 5 4 3 MLO 011246 12 27...
Страница 430: ...Setting a Unique SCSI Address the OpenVMS AXP and DEC OSF 1 AXP operating systems 16 4...
Страница 461: ......