LED Codes
Table 14–1 (Cont.) Power-Up Test Serial ROM Codes
LED
Code
Test Description
Reason for Failure
F9
Memory test with non-BCACHE
bit CLEAR, Dcache OFF, and mchk
enabled.
If read as .NE. write, send error dump
to SROM port and branch to SROM
miniconsole.
F8
Memory test with non-BCACHE bit
SET, Dcache ON, and mchk enabled.
If read as .NE. write, send error dump
to SROM port and branch to SROM
miniconsole.
F7
Memory test with non-BCACHE
bit CLEAR, Dcache ON, and mchk
enabled.
If read as .NE. write, send error dump
to SROM port and branch to SROM
miniconsole.
F6
tc register test and initialization
Should never stop here. If read as .NE.
write, send error dump to SROM port.
F5
Coreio register test and initialization
Should never stop here. If read as .NE.
write, send error dump to SROM port.
F2
Look for I/O ROM manfacturing
data.
Read of I/O ROM manfacturing data
did not return data expected. Send
error dump to SROM port and branch
to SROM miniconsole.
F1
Completed load of I/O ROM into
memory.
Should never stop here.
30
SROM code execution completed
normally.
Should never stop here.
20
Machine check.
Send mchk dump to SROM port and to
SROM miniconsole.
If a failure occurs during this portion of the power-up procedure,
perform the following steps:
1.
Verify that there is a good connection between the system
module and I/O module.
2.
Verify that all memory modules are properly installed. You
may need to reseat memory modules.
14–3
Содержание DEC 3000 600 AXP
Страница 57: ...BA47X AA Vertical Floor Stand Figure 3 8 Removing the Mounting Plate MLO 011165 4 5 3 12...
Страница 60: ...System Cover Figure 3 9 Removing the System Cover MLO 008608 2 2 1 0 1 3 15...
Страница 65: ...Removable Media Devices Figure 3 11 Loosening the Screws on the Bracket MLO 011167 1 3 20...
Страница 81: ...I O Board Figure 3 18 Removing the I O Board 1 2 3 3 4 MLO 011172 3 36...
Страница 149: ...Front View Figure 6 1 Front View Line In 1 2 3 4 5 MLO 007553 7 8 9 10 11 12 6 14 13 6 6...
Страница 152: ...Rear View Figure 6 2 Rear View ISDN S3 1 3 4 5 6 8 10 11 MLO 010854 2 1 0 3 4 5 2 7 9 6 9...
Страница 189: ...Power Supply Figure 8 10 Removing the Power Supply MLO 011224 3 4 2 8 20...
Страница 193: ...RZxx Disk Drives Figure 8 11 Removing an RZxx Drive 1 2 4 3 MLO 011225 8 24...
Страница 199: ...I O Module Figure 8 14 I O Module Cable Connections 2 1 0 MLO 011227 ISDN S3 3 4 5 1 8 30...
Страница 200: ...I O Module Figure 8 15 Removing the I O Module Side View MLO 011228 2 3 4 5 6 8 31...
Страница 204: ...Fans Figure 8 17 Removing a Fan 1 Front 2 3 4 MLO 011229 8 35...
Страница 207: ...Memory Mother Board Figure 8 18 Removing a Memory Mother Board MLO 011230 1 2 8 38...
Страница 210: ...Memory Module Figure 8 19 Removing SIMMs 1 2 MLO 011231 8 41...
Страница 291: ...Installation Procedure Figure 11 14 Front View of the System Line In 1 2 3 4 5 6 7 8 9 10 11 MLO 011260 11 27...
Страница 319: ...Installation Procedure Figure 12 14 Front View of the System Line In 1 2 11 10 9 8 7 6 5 4 3 MLO 011246 12 27...
Страница 430: ...Setting a Unique SCSI Address the OpenVMS AXP and DEC OSF 1 AXP operating systems 16 4...
Страница 461: ......