Troubleshooting Tables
2.
If connections are okay, you must run the SCSI diagnostic
(Chapter 9) or utilities (Chapter 13) to isolate a media or
controller problem.
See Chapter 7 for information on specific storage devices.
Figure 7–3 shows internal cable routing, and Figure 7–5
shows power cable routing. Figure 7–4 shows recommended
SCSI ID settings and drive placement.
Table 10–13 Drive Problems
Symptom
Possible Cause
Corrective Action
Drive does not work.
Two SCSI identifiers
are set to the same ID
number.
In console mode, enter the
SHOW DEVICE command to
check current settings. Reset
each SCSI ID to a unique
number.
A cable is loose.
Verify that all cables
connections are correct and
secure.
A drive is defective.
Run diagnostics to isolate the
fault to a FRU. Replace the
FRU.
Network
Problems
Table 10–14 describes network problems. If the corrective
actions do not correct a problem:
1.
Verify that all cable connections are correct and secure.
2.
Run NI diagnostics in service mode (for extended testing
capabilities). See Chapter 9.
Table 10–14 Network Problems
Symptom
Possible Cause
Corrective Action
An NI error message
appears when verifying
the Ethernet.
A thickwire/10BASET
terminator or cable was
not installed.
Attach an appropriate Ethernet
terminator.
(continued on next page)
10–16
Содержание DEC 3000 600 AXP
Страница 57: ...BA47X AA Vertical Floor Stand Figure 3 8 Removing the Mounting Plate MLO 011165 4 5 3 12...
Страница 60: ...System Cover Figure 3 9 Removing the System Cover MLO 008608 2 2 1 0 1 3 15...
Страница 65: ...Removable Media Devices Figure 3 11 Loosening the Screws on the Bracket MLO 011167 1 3 20...
Страница 81: ...I O Board Figure 3 18 Removing the I O Board 1 2 3 3 4 MLO 011172 3 36...
Страница 149: ...Front View Figure 6 1 Front View Line In 1 2 3 4 5 MLO 007553 7 8 9 10 11 12 6 14 13 6 6...
Страница 152: ...Rear View Figure 6 2 Rear View ISDN S3 1 3 4 5 6 8 10 11 MLO 010854 2 1 0 3 4 5 2 7 9 6 9...
Страница 189: ...Power Supply Figure 8 10 Removing the Power Supply MLO 011224 3 4 2 8 20...
Страница 193: ...RZxx Disk Drives Figure 8 11 Removing an RZxx Drive 1 2 4 3 MLO 011225 8 24...
Страница 199: ...I O Module Figure 8 14 I O Module Cable Connections 2 1 0 MLO 011227 ISDN S3 3 4 5 1 8 30...
Страница 200: ...I O Module Figure 8 15 Removing the I O Module Side View MLO 011228 2 3 4 5 6 8 31...
Страница 204: ...Fans Figure 8 17 Removing a Fan 1 Front 2 3 4 MLO 011229 8 35...
Страница 207: ...Memory Mother Board Figure 8 18 Removing a Memory Mother Board MLO 011230 1 2 8 38...
Страница 210: ...Memory Module Figure 8 19 Removing SIMMs 1 2 MLO 011231 8 41...
Страница 291: ...Installation Procedure Figure 11 14 Front View of the System Line In 1 2 3 4 5 6 7 8 9 10 11 MLO 011260 11 27...
Страница 319: ...Installation Procedure Figure 12 14 Front View of the System Line In 1 2 11 10 9 8 7 6 5 4 3 MLO 011246 12 27...
Страница 430: ...Setting a Unique SCSI Address the OpenVMS AXP and DEC OSF 1 AXP operating systems 16 4...