Chapter 6 - GP RUN Mode and Errors
GP-377 Series Users Manual
6-5
YES
Possible problems with the
PLC. Check if the PLC is
working properly.
NO
YES
Set up the correct Screen file
number.
C h a p t e r 5 ,
"Initializing the GP".
Does turning the power
ON one more time start
the display?
Go to OFFLINE mode.*1
(Press the upper left cor-
ner of the screen)
NO
See if INITIALIZE/ SET
UP SCREEN is OK.
Does the OFFLINE
menu display?
NO
Is the Status LED's
orange light ON?
YES
Connect the cable properly.
Chapter 3, "Installa-
tion and Wiring" & PLC Connec-
tion Manual
(included with the
screen creation software)
The back light has burned
out. Contact your nearest
GP distributor for the
backlight replacement.
NO
YES
*1
To make the OFFLINE screen appear, turn the power OFF, then ON, and press the
upper left corner of the screen within 10 seconds.
NO
The SIO cable,
or the AUX
cable was not
connected
properly.
YES
Is the SIO cable,
AUX cable connected
properly to this unit?
NO