Chapter 5 - Initializing the GP
GP-377 Series Users Manual
5-3
STAND-BY MODE TIME (0-255)
To protect the GP display screen, the GP is equipped with a screen saver function
that automatically turns the unit's backlight(s) OFF when no operations have
occurred for a period of time. A
"0"
entered in this field causes a normal display,
i.e. the screen is cleared after the GP's standard default time elapses.
When SYSTEM DATA AREA's (
GP-PRO/PBIII for Windows PLC
Connection Manual (included with the screen creation software)
SCREEN DIS-
PLAY OFF
*1
data is
0000h
, and the following operations are
not
performed on the
screen for the User's designated period of time, the GP's current display data is
cleared.
• Change Screen
• Touch Screen
• Alarm Display
START TIME (0-255)
This setup determines the start-up time of the GP. Use this setup to adjust the
power up sequence so that the GP starts up after the PLC.
TOUCH BUZZER SOUND
Setup whether or not the GP beeps when pressed.
PASSWORD SETUP(0-9999)
The password setting is used when changing to the Initialize Memory or Initialize
(OFFLINE mode) Screens. The password (
number
) ensures protection of the GP
settings as OFFLINE mode will not be entered inadvertently. Enter the optional
number of your choice. If you do not wish to use this setup, enter the default
0
.
*1
When using the Direct Access or the Memory Link formats, the object address
b9 or +12, respectively. (Only when all items are set within the System Data
Area.)
GP-PRO/PBIII for Windows PLC Connection Manual (included with
GP environment adjustments are made here. The SYSTEM ENVIRONMENT
SETUP includes the SYSTEM SETUP, SYSTEM DATA AREA, GLOBAL
WINDOW SETUP, and CHARACTER STRING DATA SETUP.
5.3
SYSTEM ENVIRONMENT SETUP
5.3.1 SYSTEM SETUP