vii
GP-377 Series User Guide
Preface
GP Installation
• Be sure to securely connect all cable connectors to the
GP. A loose connection may cause incorrect input or
output.
GP Wiring
• Ground the GP's FG line separately from other units’ FG
lines. Putting these FG lines too close may cause an elec-
tric shock or unit malfunction. Be sure to use a grounding
resistance of 100
Ω
Ω
Ω
Ω
Ω
or less and a 2mm
2
or thicker wire, or
your country’s applicable standard.
• Correctly wire the GP, be sure that the rated voltage and
terminal layout are within the designated range. If the
voltage supplied differs from the rated voltage, or incor-
rect wiring or grounding is performed, it may cause a fire
or unit malfunction.
• Use only the designated torque to tighten the GP's termi-
nal block screws. If these screws are not tightened firmly,
it may cause a short-circuit, fire, or GP malfunction.
• Be careful that metal filings and wiring debris do not fall
inside the GP, since they can cause a fire, GP malfunc-
tion, or incorrect operation.
GP Start-up and Maintenance
• The liquid crystal panel contains a powerful irritant and if
for any reason the panel is damaged and this liquid con-
tacts any part of your body, be sure to wash that area with
running water for 15 minutes. If any of this liquid enters
your eye, flush your eye for 15 minutes with running water
and contact a physician.
GP Disposal
• When this unit is disposed of, it should be done so ac-
cording to your country's regulations for similar types of
industrial waste.