Page 71
12.7
ADV-SETUP (ADVANCED SETUP) PARAMETERS
The following is a list of parameters that can be adjusted. For each parameter you can see the
range of values, the factory setting (default) and the unit of measure.
n Name
Description
Range
Default Units
1 IFLY
intelliflight
function
ON/OFF
OFF ----
2
THEV
thermal detect vario thres.
0 - 25
0.5
m/s
3
THET
thermal detect time thres.
1 - 30
10
sec
4
EFF
instant efficiency average
1-30
10
sec
5
EFFA
instant efficiency for HW
1-100
3
sec
6 PHON
headphone
output
ON/OFF
OFF ----
7
POWE
gps mode (Leonardo only)
STD/ECO/EC2
ECO
----
8 POLA
active
polar
OFF/P1/P2/P3 OFF ----
9-11
P1-A P1-B P1-C
polar 1 coeff.
xxx
---- ---
12-14
P2-A P2-B P2-C
polar 2 coeff.
xxx
---- ----
15-17
P3-A P3-B P3-C
polar 3 coeff.
xxx
---- ----
18 MCRA
McCready value
0.2 - 30
10
min
19 MCRE
McCready equiv average time 0.1 – 3
0
sec
12.8
RESTORE FACTORY SETTINGS
To restore the factory settings (default parameters) and default screen setups, press and
hold down the
key as you turn vario on. Keep the
key pressed until a message “FACTORY
SET?” appears, then confirm with “YES” or “NO”.