background image

2

FCC COMPLIANCE

CAUTION: The user should make no field changes or modifications to the unit. Any change or
modification to the equipment will void the user's authority to operate the unit, and render
the equipment in violation of FCC part 15. Any tampering with this product will void the
warranty.

This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy. If not installed and used in accordance with the instructions, the
radio signals may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:

1. Reorient or relocate the receiving antenna.

2. Increase the separation between the equipment and receiver.

3. Connect the equipment to an outlet on a circuit different from that to which the receiver is

connected.

4. Consult the dealer or an experienced radio/TV technician.

This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.

3

TABLE OF CONTENTS

1. Introduction …………………………………………………………………………4

2. Getting to Know the Remote

…………………………………………………………4

3. Inserting Batteries into the Remote ……………………………………………………6

4. Set Up (Language, Date & Time) ………………………………………………………6

5. Programs A-B-C ………………………………………………………………………7

5.1  Irrigation Program for a Group of Valves ……………………………………………7

5.2  Selecting a Program (Weekly or Cyclical) …………………………………………7

5.3  Start Time ………………………………………………………………………8

5.4  Seleecting Valves …………………………………………………………………8

5.5  Irrigation Duration per Valve ………………………………………………………9

6. Independent I Program ………………………………………………………………9

6.1  Selecting a Valve …………………………………………………………………9

6.2  Irrigation Duration per Valve ………………………………………………………9

6.3  Weekly Programming ……………………………………………………………10

6.4  Cyclical Programming ……………………………………………………………10

7. Fertilizing ……………………………………………………………………………11

8. Sensor ………………………………………………………………………………11

9. Percentage (%) ………………………………………………………………………12

10. Rain Off ……………………………………………………………………………12

11. Manual

……………………………………………………………………………12

12. Controller ……………………………………………………………………………14

12.1  Controller Operation ……………………………………………………………14

12.2  New Controller Added to System ………………………………………………14

12.3  Clear or Erase Program …………………………………………………………15

12.4  Load Programs from Controller …………………………………………………15

12.5  Delete Controller from System …………………………………………………15

12.6  Rename Controller ……………………………………………………………16

12.7  Send Program from Remote to Controller ………………………………………16

12.8  Receive Program from Controller ………………………………………………17

12.9  Status Check of Controller in Field ………………………………………………17

13. Home Files …………………………………………………………………………18

13.1  Save to File ……………………………………………………………………18

13.2  Load to Edit ……………………………………………………………………18

14. Summary – Programming the System

………………………………………………19

15. Warranty ……………………………………………………………………………20

Содержание 600C

Страница 1: ...nguages English Spanish Italian and French Operates numerous controllers The remote stores the memory of up to 50 controllers Weekly or cyclic irrigation programs for an individual valve or a group of...

Страница 2: ...t to an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician This device complies with part 15 of the FCC rules Operati...

Страница 3: ...ed successfully the message Send Successful is displayed on the screen con rming reception of the program The Remote Offers Two Types of Irrigation Programs 1 Irrigation programs for a group of valves...

Страница 4: ...offers two valve programming options 1 Program A B C a common program for a selected number of valves 2 Independent I program a separate program for each valve Turn the selector to PROGRAM position 5...

Страница 5: ...m You can assign up to 6 valves to each program You can sign each valve to one program only Turn the selector to VALVES position Press The cursor appears below the rst selected valve Use the to set th...

Страница 6: ...ning of the rst cycle 0 open on the current day 1 open in one days time 2 open in 2 days time etc You have now completed programming the rst individual valve including selecting a valve irrigation dur...

Страница 7: ...number Use or to select the desired operation see all the options on the next page After you select the option send the command to the controller press SEND The Remote displays SENDING in the bottom l...

Страница 8: ...name to the controller for your convenience Press until the cursor is below the required mode Save Cancel or Clear Press to select the required mode and wait for con rmation Save Saves the name Cancel...

Страница 9: ...the selector to CONTROLLER position Press until the cursor appears below the word Receive Press the screen changes The command is Receive Use or to select the controller s ID and name Press the scree...

Страница 10: ...is displayed in the bottom line The screen returns to the main menu The program is residing in the editor for review change or for sending to a chosen controller 19 14 SUMMARY PROGRAMMING THE SYSTEM...

Страница 11: ...this product and any damage resulting from such use shall not be the responsibility of DIG CORPORATION There are no warranties which extend beyond the description on the face hereof In the case of pu...

Отзывы: