background image

4

1. INTRODUCTION

Thank you for purchasing a DIG 600C Remote Control Handset. This manual is designed to help set
up the 600C handset. After reading the manual and getting familiarized with the basic functionality
of the device, use the manual as reference for less common tasks in the future.

Please take the time to read through the enclosed instructions and follow them step-by-step. If you
have any questions, please call our customer service line 1-800-322-9146.

2. GETTING TO KNOW THE REMOTE

1) Antenna

2) Display

3) Program selector

4) Battery compartment

5) SEND and RECEIVE pushbuttons

6) Programming pushbuttons

b

d

e

c

g

f

5

General Information

The Remote is easily operated by a selector and five buttons. You can save programs in home files
(up to 3 programs), or send the programs directly to a controller. Programs that were sent to the
controller and received are saved in the memory of the remote according to the controller's code
(up to 50 controllers).

By using the remote you can transfer programs from home files to controllers, modify programs
located in the controller and create new programs.

NOTE: The irrigation is set in the remote only and not in the controller itself.

The controller receives the programs and operates the valves. To transmit programs to the
controllers, ascertain that the remote is located within the reception range of the controller (up to
300' line of sight). When the transmission is completed successfully, the message 

Send Successful

is displayed on the screen, confirming reception of the program.

The Remote Offers Two Types of Irrigation Programs

1. Irrigation programs for a group of valves

2. An irrigation program for an individual valve

Additional Options

Fertilizing program for each valve

An Irrigation Program for a Group of Valves (see section 5.1, pg. 7)

You can program three programs: A, B and C.

For each program, select the irrigation days on which the valves will operate. Set a start time for the
first valve only and define the irrigation duration for each valve separately. The valves open in
sequence, according to their serial number on the display. When the first valve shuts off the second
valve opens, etc. Only one valve operates at any given moment. When setting programs (A, B, C)
with overlapping irrigation times, program A starts first and program B starts only after program A
ends. Program C opens after program B ends.

When no fertilization program is set, two valves can open simultaneously.

Independent I Program for an Individual Valve (see section 6.0, pg.9)

Use this method to define an individual program for each valve. Select the desired valve first and
then proceed to define the irrigation program: set watering duration, irrigation days or irrigation
cycles and the start time of that valve.

General Description

Program the controller using the 16 position selector and 5 buttons:

Increase button – to add to the selected value and confirm activity in certain conditions

Decrease button – to deduct from the given value

Scroll up button

Scroll down button

Opens the field and moves from one field to another

Содержание 600C

Страница 1: ...nguages English Spanish Italian and French Operates numerous controllers The remote stores the memory of up to 50 controllers Weekly or cyclic irrigation programs for an individual valve or a group of...

Страница 2: ...t to an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician This device complies with part 15 of the FCC rules Operati...

Страница 3: ...ed successfully the message Send Successful is displayed on the screen con rming reception of the program The Remote Offers Two Types of Irrigation Programs 1 Irrigation programs for a group of valves...

Страница 4: ...offers two valve programming options 1 Program A B C a common program for a selected number of valves 2 Independent I program a separate program for each valve Turn the selector to PROGRAM position 5...

Страница 5: ...m You can assign up to 6 valves to each program You can sign each valve to one program only Turn the selector to VALVES position Press The cursor appears below the rst selected valve Use the to set th...

Страница 6: ...ning of the rst cycle 0 open on the current day 1 open in one days time 2 open in 2 days time etc You have now completed programming the rst individual valve including selecting a valve irrigation dur...

Страница 7: ...number Use or to select the desired operation see all the options on the next page After you select the option send the command to the controller press SEND The Remote displays SENDING in the bottom l...

Страница 8: ...name to the controller for your convenience Press until the cursor is below the required mode Save Cancel or Clear Press to select the required mode and wait for con rmation Save Saves the name Cancel...

Страница 9: ...the selector to CONTROLLER position Press until the cursor appears below the word Receive Press the screen changes The command is Receive Use or to select the controller s ID and name Press the scree...

Страница 10: ...is displayed in the bottom line The screen returns to the main menu The program is residing in the editor for review change or for sending to a chosen controller 19 14 SUMMARY PROGRAMMING THE SYSTEM...

Страница 11: ...this product and any damage resulting from such use shall not be the responsibility of DIG CORPORATION There are no warranties which extend beyond the description on the face hereof In the case of pu...

Отзывы: