12
9. PERCENTAGE (%)
Irrigation Percentage – Change the
Irrigation Duration in %
You have an option to increase or decrease
the duration of the irrigation in %, in all the
valves.
You have 2 options:
1. An identical increase in % for all valve
groups
2. A different percent for each group: A, B, C and independent I program.
90% to 10% – a decrease at intervals of 10%
110% to 190% – an increase at intervals of 10%
NOTE: When a % change rate was set for one of the programs (A, B, C, I) you cannot access
All. When a % change rate was set for ALL you cannot access A, B, C, I.
Turn the selector to PERCENTAGE position
Press
until the cursor appears below the desired program, A, B, C, I or All. Use
or
to select
the program. Press
until the cursor appears below the desired % digit. Use
to set increase %.
Use
to set the decrease %.
10. RAIN OFF
Use this option to cancel the control of the remote over some valves or all valves, temporarily
(e.g., when it rains). The irrigation program is saved but the irrigation will not start.
You can lock out all the valves together in ALL position and also lockout one valve or several valves
according to valves assignment to program A, B, C, or I. The lockout is for 1 day up to 99 days.
When the Rain Off duration ends, the controller resumes the original program.
NOTE: If you locked out a valve or program you cannot lockout all the valves through ALL.
If all the programs and valves were locked out through All, you cannot lockout single
programs.
Turn the selector to RAIN OFF position
Press
until the cursor appears below the
desired program. Use
or
to select the
program.
Press
until the cursor appears below the
days digit. Use
or
to set the desired
number of lockout days (1-99 days). Select another program and additional Rain Off days in the
same way.
11. MANUAL
This mode enables you to:
• Open a program/valve manually from the remote
• Shut a currently open valve
• Close the program
• Shut all the currently operating valves/programs or those in line to start
• Send from the Remote to the controller: current time, increase % of the irrigation, Rain Off
• Serial test of all the valves
Turn the selector to MANUAL position
13
Use
or
to select the desired controller (according to code number). Use
or
to select the
desired operation (see all the options on the next page). After you select the option, send the
command to the controller – press SEND. The Remote displays SENDING in the bottom line. If the
message is transmitted, Successfully Sent is displayed. If the communication fails, Out of Range is
displayed.
• A valve with no defined irrigation duration cannot be opened manually.
• The fertilizing valve opens with the valves to which it is assigned and according to the
fertilizing %.
• You may use
or
to move among the programs and the individual valves continuously. You
cannot open individual valves which are assigned to a program.
NOTE: Manual operation or any change in the program stops the operation of valves which
are open at that time.
In a cyclical program, the irrigation starts again. Sending current time, irrigation %, Rain Off
does not stop the operation of the valves.
Available Commands in Manual Mode
Open/Close All
Open- set the valves/programs sequentially which are programmed
Open A
Open- program A (if it includes programmed valves)
Open B
Open- program B (if it includes programmed valves)
Open C
Open- program C (if it includes programmed valves)
Open I
Open/ only valves with set irrigation duration
Open 1
Open/ valve No. 1 (only if it is set as an independent)
Open 2
Open/ valve No. 2 (only if it is set as an independent)
Open 3
Open/ valve No. 3 (only if it is set as an independent)
Open 4
Open/ valve No. 4 (only if it is set as an independent)
Open 5
Open/ valve No. 5 (only if it is set as an independent)
Open 6
Open/ valve No. 6 (only if it is set as an independent)
Open All
Open all the valves
Close A
Close program A
Close B
Close program B
Close C
Close program C
Close I
Close all the individual valves/cancel valves in line
Shut irrigation valve Shut the currently irrigating valve and open the next (if any).
Current time
Send current time to the controller.
Serial test
Close all irrigation activities, perform a serial test – open shut all the valves,
one after the other, each for 10 seconds.
The communication line is displayed after pressing SEND button. When communication is
successful: Success indicates successful transmission. When communication fails: Fail indicates
that you are out of range and must go closer to the controller.
NOTE: Manual operation or any change in the program stops the operation of valves which
are open at that time.