![Dickey-John seed manager Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/dickey-john/seed-manager/seed-manager_operators-manual_2494907059.webp)
OPERATOR’S MANUAL
Seed Manager SE
11001-1359A-200810
ALARMS / 57
FAN SPEED LO LIMIT WARNING
Fan Speed Lo Limit Warning occurs when any fan speed falls below the
value entered for Fan Speed Lo Limit in the SETUP MODE. The alarm
beeps for three (3) seconds and the fan speed sensor number and actual
fan speed, in RPM, display. If multiple fan speed sensors fall below the
limit, the fan speed sensor numbers display sequentially, along with their
respective fan speeds. (
Figure 69
) shows a Fan Speed Lo Limit Warning
on fan speed sensor two (2) with a fan speed of 167 RPM.
Figure 69
Fan Speed Lo Limit Warning Display
SHAFT SPEED HI LIMIT WARNING
Shaft Speed Hi Limit Warning occurs when any shaft speed exceeds the
value entered for Shaft Speed Hi Limit in the SETUP MODE. The alarm
beeps for three (3) seconds and the shaft speed sensor number and actual
shaft speed, in RPM, display. If multiple shaft speed sensors exceed the
limit, the shaft speed sensor numbers display sequentially, along with their
respective shaft speeds. (
Figure 70
) shows a Shaft Speed Hi Limit Warning
on shaft speed sensor one (1) with a shaft speed of 1,592 RPM.
Figure 70
Shaft Speed Hi Limit Warning Display
Содержание seed manager
Страница 4: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 2 SAFETY NOTICES...
Страница 6: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 4 INTRODUCTION...
Страница 22: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 20 INSTALLATION AND SETUP...
Страница 46: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 44 STARTUP...
Страница 64: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 62 SELF TEST ERROR CODES...
Страница 70: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 68 SELF TEST ERROR CODES...