![Dickey-John seed manager Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/dickey-john/seed-manager/seed-manager_operators-manual_2494907024.webp)
OPERATOR’S MANUAL
Seed Manager SE
11001-1359A-200810
22 / STARTUP
SELECT
The Select button changes constants in the Setup Mode as explained in the
Setup Mode section. To move the selected digit to the next digit, press the
SELECT switch.
SET
The Set button changes constants in the Setup Mode as explained in the
Setup Mode section. To increase the selected digit by one, press the SET
switch. SET can also toggle a selection between ON and OFF for example.
START STOP RESET
This switch is used in multiple modes for multiple purposes. Some
examples are as follows. Used in the Operate Mode Seed Count and
Distance Accumulator functions to start or stop the accumulations. It is also
used in Setup Mode Distance Calibration, Automatic Configuration, and
Sensor Self Test functions to start or stop the test. Other functions include
Clearing the Run Hours, Area Accumulators, Seed Count, Distance
Accumulator, and simply clearing digits when editing Setup constant
values.
BACK
This switch is used in multiple modes for several purposes. Some
examples are as follows. Used in the Operate Mode Population and
Spacing functions to step to the previous row display. It is also used in
Setup Mode to return to the previous Setup Mode screen.
OPERATE 1
This switch is used to select Population, Spacing, or Ground Speed Mode.
Successive presses of the switch will change to the next mode.
SELECT
SET
START
STOP
RESET
l l l l
Содержание seed manager
Страница 4: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 2 SAFETY NOTICES...
Страница 6: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 4 INTRODUCTION...
Страница 22: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 20 INSTALLATION AND SETUP...
Страница 46: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 44 STARTUP...
Страница 64: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 62 SELF TEST ERROR CODES...
Страница 70: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 68 SELF TEST ERROR CODES...