OPERATOR’S MANUAL
Seed Manager SE
11001-1359A-200810
STARTUP / 25
Figure 16
Setup Mode Parameters
To exit the Setup Mode, press any of the three Operate switches. Exiting
automatically stores the last constant changed.
IMPORTANT:
If the Number of Seed Modules,
Number of Fan Speed Sensors,
Number of Shaft Speed
Sensors, or Number of Pressure
Sensors is set to “0” or another
value below the maximum, the
appropriate subcategory
screens will not display.
Order
Setup Mode
Default
Minimum
Maximum
1
Seed Flow
00
00
10
2
Population Hi Limit
0034.0
0000.0
9999.9
3
Population Lo Limit
0026.0
0000.0
9999.9
4
Row Width
030.0
001.0
999.9
5
Implement Width
N/A
0001.0
9999.9
6
Ground Speed Source
d1
N/A
N/A
7
Distance Calibration
6096
250
9999
8
Automatic Configuration
N/A
N/A
N/A
9
Split Row Configuration
00
00
20
10
Number of Seed Modules
1
1
6
10A Number of Seed Sensors Module 1
01
01
16
10B Number of Seed Sensors Module 2
01
01
16
10C Number of Seed Sensors Module 3
01
01
16
10D Number of Seed Sensors Module 4
01
01
16
10E Number of Seed Sensors Module 5
01
01
16
10F Number of Seed Sensors Module 6
01
01
16
11
Row Status
ON
N/A
N/A
12
Total Number of Rows Configured
N/A
01
96
13
Number of Fan Speed Sensors
0
0
2
13A Fan Speed Sensor 1 Constant
000.0
000.0
999.99
13B Fan Speed Sensor 1 Hi Limit
00065
00000
99999
13C Fan Speed Sensor 1 Lo Limit
00045
00000
99999
13D Fan Speed Sensor 2 Constant
000.0
000.00
999.99
13E Fan Speed Sensor 2 Hi Limit
00065
00000
99999
13F Fan Speed Sensor 2 Lo Limit
00045
00000
99999
14
Number of Shaft Speed Sensors
0
0
3
14A Shaft Speed Sensor 1 Constant
000.00
000.00
999.99
14B Shaft Speed Sensor 1 Hi Limit
00065
00000
99999
14C Shaft Speed Sensor 1 Lo Limit
00045
00000
99999
14D Shaft Speed Sensor 2 Constant
000.00
000.00
999.99
14E Shaft Speed Sensor 2 Hi Limit
00065
00000
99999
14F Shaft Speed Sensor 2 Lo Limit
00045
00000
99999
14G Shaft Speed Sensor 3 Constant
000.00
000.00
999.99
14H Shaft Speed Sensor 3 Hi Limit
00065
00000
99999
14I Shaft Speed Sensor 3 Lo Limit
00045
00000
99999
15
Number of Hopper Sensors
0
0
7
16
Number of Pressure Sensors
0
0
2
16A Pressure Sensor 1 Hi Limit
000.0
000.0
999.9
16B Pressure Sensor 1 Lo Limit
000.0
000.0
999.9
16C Pressure Sensor 2 Hi Limit
000.0
000.0
999.9
16D Pressure Sensor 2 Lo Limit
000.0
000.0
999.9
17
Blockage Mode Configuration
0
0
2
18
Population Filter
00
00
99
19
Population Scalar
100
001
999
20
Sensor/Module Self-Test
N/A
N/A
N/A
21
English/Metric Units
English
N/A
N/A
Содержание seed manager
Страница 4: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 2 SAFETY NOTICES...
Страница 6: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 4 INTRODUCTION...
Страница 22: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 20 INSTALLATION AND SETUP...
Страница 46: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 44 STARTUP...
Страница 64: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 62 SELF TEST ERROR CODES...
Страница 70: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 68 SELF TEST ERROR CODES...