OPERATOR’S MANUAL
A warning message displays indicating that material will dispense
when channel is activated. Ensure all personnel are clear before
starting the next step.
3. When ONLY the liquid channel is propelled by the hydraulic system,
start the engine keeping the vehicle stationary.
4. Engage the hydraulic system and increase the engine RPMs to normal
operating range.
5. Press “R” to run the liquid pump and start the calibration routine. For
flow meter based systems, use the Rate Increase/Decrease
buttons on the switch module to obtain an adequate discharge
rate.
The number displayed indicates the accumulating count from the
APR sensor.
6. When a sufficient amount of liquid has dispensed, press “S” to stop.
– For a flow meter-based system, a screen appears showing the
previous K Factor and the sensor counts accumulated during the
current run.
– For a pressure-based system, the previous nozzle constant and
collection time display. The screen asks for an entry of gallons
before proceeding.
7. Perform the next step while the screen waits for the results.
8. Weigh the material caught and calculate the amount dispensed in
gallons.
9. Enter the number into the console and press Enter.
IMPORTANT: The amount dispensed value must be entered to adjust
the K Factor value; otherwise the K Factor will remain at
the current setting.
10. Press “D” when finished. The flow meter constant is now stored and
displayed on this screen and on the Liquid Configuration screen for this
material.
11. For maximum accuracy, repeat the entire procedure at least three
times.
12. Average the results and enter the average as the final K Factor
constant.
13. Record the material’s K Factor constants on the Calibration Data
Records sheets at the rear of this manual.
14. Repeat this procedure for each liquid material used.
110 / CALIBRATIONS
Flex4 Pro
TM
Control System
6010541 Rev A
Содержание Flex4
Страница 1: ...FLEX4 PRO PUBLIC WORKS CONTROL SYSTEM Operator s Manual SINCE 1966 FLEX PRO...
Страница 5: ...OPERATOR S MANUAL Flex4 ProTM Control System 6010541 Rev A SAFETY NOTICES 2...
Страница 7: ...OPERATOR S MANUAL 4 INTRODUCTION Flex4 ProTM Control System 6010541 Rev A...
Страница 29: ...OPERATOR S MANUAL 26 INSTALLATION Flex4 ProTM Control System 6010541 Rev A...
Страница 49: ...OPERATOR S MANUAL 46 OPERATION Flex4 ProTM Control System 6010541 Rev A...
Страница 55: ...OPERATOR S MANUAL 52 FLEX4 PROTM PROGRAMMING Flex4 ProTM Control System 6010541 Rev A...
Страница 105: ...OPERATOR S MANUAL 102 SYSTEM PROGRAMMING Flex4 ProTM Control System 6010541 Rev A...
Страница 111: ...OPERATOR S MANUAL Figure 95 Granular Drop Test Procedure 108 CALIBRATIONS Flex4 ProTM Control System 6010541 Rev A...
Страница 116: ...OPERATOR S MANUAL Figure 98 Spinner System Response Screens Flex4 ProTM Control System 6010541 Rev A CALIBRATIONS 113...
Страница 123: ...OPERATOR S MANUAL 120 CALIBRATIONS Flex4 ProTM Control System 6010541 Rev A...
Страница 131: ...OPERATOR S MANUAL 128 CAPTURE SCREEN SHOT Flex4 ProTM Control System 6010541 Rev A...
Страница 139: ...OPERATOR S MANUAL 136 DIAGNOSTICS Flex4 ProTM Control System 6010541 Rev A...
Страница 145: ...OPERATOR S MANUAL 142 TROUBLESHOOTING Flex4 ProTM Control System 6010541 Rev A...
Страница 150: ...6010541 Rev A...
Страница 151: ...OPERATOR S MANUAL APPENDIX C Flex4 ProTM Control System 6010541 Rev A APPENDIX C 147...