![Dialogic SS7G2X Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/dialogic/ss7g2x/ss7g2x_user-manual_2493101082.webp)
82
Chapter 6 Command Definitions
6.8.3
MMLOS – MML Log Off Set
Synopsis
This command sets the current log-on time-out (
TLO
) and timeout warning (
TLOW
) parameters. If
TLOW
is
set to zero, the automatic time-out is disabled. If port (
PORT
) is omitted, the command applies to all ports.
Syntax
MMLOS:{[
TLO
=,][
TLOW
=,]}[
PORT
=,];
Prerequisites
None
Attributes
CONFIG
Examples
MMLOS:
TLO
=35;
MMLOS:
TLOW
=19;
6.8.4
MMPTC – MML Port Change
Synopsis
This command sets the data input/output parameters for serial and telnet data ports.
Note: Only serial port 2 (COM2) is accessible by the user.
Syntax
MMPTC:
PORT
=,{[BAUD=,][
DBITS
=,][
PARITY
=,][
SBITS
=,][
LINES
=,][
PTMODE
=,]};
Prerequisites
•
No user must be logged on to the port affected.
•
For the
telnet
ports, only the
LINES
parameter can be changed.
Attributes
CONFIG
Examples
MMPTC:
PORT
=2,BAUD=300;
MMPTC:
PORT
=2,
SBITS