Chapter 6 Command Definitions
6.14.9
STRDP – Status Remote Data Centre Print
Synopsis
This command requests a status report for the Remote Data Centres (RDCs). The status can be one of the
following:
•
OK - The RDC is available to receive data.
•
Initiating - Initiating connection to the RDC.
•
Failed - The RDC is not available to receive data.
•
Blocked - The RDC is user blocked from receiving data.
File transfer is to the lowest numbered available RDC.
Note: If the system does not have an
IPADDR
, then status indicates OK for communication with the
RDC; however, no data can be transferred.
Syntax
STRDP;
Prerequisites
None
Attributes
None
Examples
STRDP;
Output Format
Remote Data Centre Status
RDC IPADDR RDCSTAT
1 25.03.203.52 Initiating
2 102.03.211.140 OK
EXECUTED