![Dialogic SS7G2X Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/dialogic/ss7g2x/ss7g2x_user-manual_2493101065.webp)
65
Dialogic
®
SS7G2x Signaling Server SGW Mode User Manual Issue 4
6.5.27
CNXCP – Configuration Cross Connect Print
Synopsis
This command is used to obtain a printout of Cross Connect connection path(s).
Syntax
CNXCP:
PCM
=;
CNXCP:
OTS
=;
CNXCP;
Prerequisites
None
Attributes
None
Examples
CNXCP:
PCM
=1-2;
CNXCP:
OTS
=1-1-16;
CNXCP;
Output Format
Path Configuration
OTS ITS DUPLEX
1-1-16 2-1-16 Y
EXECUTED