![Dialogic SS7G2X Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/dialogic/ss7g2x/ss7g2x_user-manual_2493101074.webp)
74
Chapter 6 Command Definitions
6.6.10
C7SLC – CCS SS7 Signaling Link Change
Synopsis
This command is used to change the attributes of an SS7 signaling link.
Syntax
C7SLC:
C7LINK
=,{[
EQU
=,][
SNLINK
=,][
TS
=,][
M56K
=,][
PCR
=,]};
Prerequisites
•
The specified link has already been initiated.
•
The specified
PCM
time slot is not already assigned elsewhere in the system.
•
The
PCM
on which the timeslot exists has been initiated.
•
If specified, the board on which the
EQU
exists has been initiated.
•
If specified, the
PCM
on which the timeslot exists has been initiated.
•
The timeslot is a valid timeslot number for the
PCM
type (up to 31 for a E1 PCM and 24 for a T1 PCM).
•
The signaling processor specified by the
EQU
parameter must be equipped with a valid board type and
not already assigned to a link.
•
All links within the link set must be blocked.
•
If the
EQU
,
PCR
or
M56K
parameters are specified the link must be blocked and C7 links
EQU
board must
be blocked. To change the other parameters on the C7 link, the link must be inhibited.
•
If
M56K
is set to either 1 or 2, all links on the same board for which M56K is set to 1 or 2 must also use
the same M56K value (that is, only one mode of 56kbits/s operation is supported on any board at one
time. However, it is possible for some links to operate at 64kbits/s, while others operate at 56kbits/s).
•
The signaling processor specified by the
EQU
parameter must be equipped with a valid board type and
not already assigned to a link.
•
All links within the link set must be blocked.
Note: After blocking, an SS7 link cannot be unblocked until all the boards processing the SS7 signaling
are blocked and then unblocked.
•
If the
EQU
,
PCR
or
M56K
parameters are specified, the link must be blocked and the C7 link’s EQU board
must be blocked. To change the other parameters on the C7 link, the link must be inhibited.
•
If
M56K
is set to 3 or 4, the
TS
cannot be specified and if M56K is not set to 3 or 4, the
EQU
must be
specified.
•
Only
EQU
signaling processors 1 and 2 can be used if
M56K
is 3 or 4.
•
If an
SNLINK
is present, the
EQU
,
TS
,
M56K
and
PCR
cannot be present.
•
If an
SNLINK
is specified, it’s
SNTYPE
must be M2PA.
•
If an
SNLINK
is specified, it must be initiated, blocked and cannot be associated with any other SS7 link.
•
The command cannot change between
SNLINK
and
EQU
type C7LINKs.
•
SS7 links can use signaling processors 1 to 4 on a SPCI4 or SPCI2S board or 1 to 64 on a SS7HDP board.
Attributes
CONFIG
Examples
C7SLC:
C7LINK
=4,
EQU
=2-3,
TS
=3-3-16,
M56K
=1;