background image

JINDLU04 Rev G 21/04/16 

2.

 

Remove the log retainer by lifting it 
clear of the two support pins. 
 

 

 

3.

 

Remove the baffle brick by lifting it 
up, sliding it to the right and then 
lowering the left hand edge into the 
firebox. 

 

 

4.

 

Remove the two side bricks by lifting 
them up to release them from the 
slots in the base brick. Swing the 
bricks into the centre and remove 
them from the stove.  
 

 

5.

 

Remove the three rear brick sections 
noting their positions and orientation.  
 

 

 

6.

 

Lift up and remove the base brick. 

 

7.

 

Remove the Air Valve Cassette by 
removing the socket screw holding it 
in place, turning both air controls to 
the fully open position (clockwise) 
and then gently pulling on the fascia 
to slide the cassette out from under 
the firebox. 

N.B

DO NOT Remove the 

Air Valve Cassette with the controls 
in the closed position as this will 
damage the valve gaskets.  
 
 

 

Socket screw 

Содержание CVSDL04-FP3BLK

Страница 1: ...JINDLU04 Rev G 21 04 16 Wood Burning Inset Stove Installation and Operating Instructions CVSDL04 FP3BLK CVSDL04 FP4BLK CVSDL04FP3PWT CVSDL04 FP4PWT R4...

Страница 2: ...s Park Exeter United Kingdom EX1 3QS DSEN13229 Inset Wood Burning Stove Appliance Mass 70kg Efficiency 79 Nominal Heat Output 4 9kW Mean Co Emission 13 O2 0 09 Mean OGC Emission 13 O2 99 mg m3 n Mean...

Страница 3: ...ons scheme it is a legal requirement in the UK to notify your local building control body in advance of any work starting HEALTH AND SAFETY PRECAUTIONS Special care must be taken when installing the s...

Страница 4: ...stent fume emission must not be tolerated This appliance should not be operated with the doors open If fume emission does persist then the following action should be taken immediately Open Doors and w...

Страница 5: ...terials The dimensions of the opening should be at least those shown in the diagram Ensure there is a sufficient overlap where the convection chamber flange meets the face of the opening If not either...

Страница 6: ...the kit before proceeding HEARTH REQUIREMENTS A constructional hearth with a minimum thickness of 125mm should be provided The constructional hearth should be made of solid non combustible material an...

Страница 7: ...cordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS EN 1856 can be used These chimneys must be fitted in accordance with the manufacturer s ins...

Страница 8: ...xings and the flue outlet as well as protect the internal components from damage during the installation process 1 To open the stove door press on the door lever to release it from the latch Swing the...

Страница 9: ...s into the centre and remove them from the stove 5 Remove the three rear brick sections noting their positions and orientation 6 Lift up and remove the base brick 7 Remove the Air Valve Cassette by re...

Страница 10: ...ce 2 Drill a 6mm hole into the hearth in the centre of the base plate fixing hole Use the screw supplied to fix the stove in place Any voids around the stove must be In filled with vermiculite concret...

Страница 11: ...hen filled and sealed once the installation is complete Alternatively a connection can be made using a register plate although it will be necessary to allow access for fitting the flue pipe to the reg...

Страница 12: ...d it when in the closed position COMMISSIONING Upon completion of the installation allow a suitable period of time for any fire cement and mortar to dry out A small fire may then be lit and the instal...

Страница 13: ...or unseasoned wood will create tar deposits in the stove and chimney increase harmful emissions and will not produce a satisfactory heat output Do not burn waste mineral fuel or treated or painted woo...

Страница 14: ...he stove door Once the kindling is well alight open the door and build the fire by gradually adding slightly larger pieces of wood closing the door afterwards Once the fire is established close the Ig...

Страница 15: ...can be replaced with new available from your dealer Air Valve Cassette this should be removed and cleaned monthly to remove any ash that may be in the controls N B Make sure that controls are in the...

Страница 16: ...t may therefore be necessary to adjust the door catch to maintain the door seal To adjust the catch slacken the two set screws on the catch bar and adjust the position of the catch bar as necessary Ai...

Страница 17: ...JINDLU04 Rev G 21 04 16 Stove Spares BODY SPARES...

Страница 18: ...JINDLU04 Rev G 21 04 16 Stove Spares DOOR SPARES...

Страница 19: ...JINDLU04 Rev G 21 04 16 Stove Spares AIR VALVE CASSETTE SPARES...