Revised 11-07-11 

 

 
 

 
 

SAN REMO 

8, 12, 20, Maxi 

 
 

FREESTANDING 

WOOD BURNING 

BOILER 

STOVES 

 

 

Installation and Operating 

Instructions 

 
 

Please hand these instructions to the stove user when the installation 
is complete. Leave the system ready for operation and instruct the 
user in the correct use of the appliance and operation of controls. 
 
Installation – Must be installed by a qualified plumber or suitably 
qualified fitter  

 

Содержание Maxi

Страница 1: ...ng Instructions Please hand these instructions to the stove user when the installation is complete Leave the system ready for operation and instruct the user in the correct use of the appliance and op...

Страница 2: ...W Boiler San Remo 12kW Boiler San Remo 20kW Boiler San Remo Maxi Boiler Total Heat Output kW 8 4 13 0 20 9 27 1 Output to Water kW 5 4 8 2 11 8 15 2 Output to room kW 3 0 4 8 9 1 11 9 Efficiency 77 7...

Страница 3: ...equivalent plumber or Heating Engineer with experience in fitting boiler stoves San Remo Stoves cannot accept responsibility for any fault arising through incorrect installation Remove the plastic bag...

Страница 4: ...o it s back 2 Ensure legs and fixings are present as shown 3 Ensure the tapped holes on the base are free from obstruction Use a sharp screwdriver to remove any fire cement Secure the legs and fixings...

Страница 5: ...below fixed to the top of the stove If a back flue outlet is required then remove the blanking plate from the back and fit the collar in its place Refit the blanking plate to the top of the stove 2 To...

Страница 6: ...h Pan Tool 1 Coal Catcher 1 Baffle Plate 1 Legs 4 Leg Height Screws M8 4 Leg Screws M8 8 Leg Washers M8 8 Flue Collar 1 Flue Collar Screws M6 4 Flue Collar Nuts M6 4 Flue Collar Washers M6 4 Grate Sur...

Страница 7: ...sits may be brushed off and if necessary blackened with a proprietary stove polish Important Warning This stove must not be installed into a chimney that serves any other heating appliance No purpose...

Страница 8: ...e old fireplace should be filled in so that there is a smooth streamlined entry into the flueway The length of any horizontal run of flue pipe must not exceed 125mm It is essential that all connection...

Страница 9: ...Revised 11 07 11 Boiler Connection...

Страница 10: ...ch as a neutralizer When fitting this type of system the neutralizer manufacturer s instructions must be followed Do Fit an open cold feed and header expansion tank with separate cold feed and vent pi...

Страница 11: ...To prevent boiler corrosion due to condensation it is necessary to maintain the return water temperature above 45 C This can be achieved by the use of a LOWLIMIT thermostat on the return pipe from the...

Страница 12: ...normal with the obvious notable features of CLEAN GLASS Never clean glass when stove is hot Always use stove glass cleaner which is available from your stove retailer However for this product to work...

Страница 13: ...regularly Use the T end of tool to lift the ashpan out of the stove Notes on Wood burning With a full load of wood the stove will need to be refuelled approximately every 1 5 hours Wood can be stacke...

Страница 14: ...little and often rather than in large pieces When possible refuel the stove before the bed has gone too low Open the primary air controls by about two turns and add the fuel Allow the fuel to burn for...

Страница 15: ...ional fumes from de ashing and refuelling may occur Persistent fume emission must not be tolerated If fume emission does persist then the following immediate action should be taken 1 Open doors and wi...

Страница 16: ...cal San Remo Stove retailer will be pleased to supply spare parts and to provide any other information you require 7 Can the doors be left open while burning For safety and heat efficiency the doors s...