DI Lusso CVSDL04-FP3BLK Скачать руководство пользователя страница 4

JINDLU04 Rev G 21/04/16 

S

AFETY

 

WARNING – 

This appliance will be hot when 

in operation and due care should be taken. 
The supplied operating tool or gloves may be 
used to open the door and operate the air 
controls. 

AEROSOLS – 

Do not use an aerosol spray on 

or near the stove when it is alight.

 

FIRES CAN BE DANGEROUS

 – Always use a 

fireguard in the presence of children, the 
elderly or the infirm. The fireguard should be 
manufactured in accordance with BS8423 – 
Fireguards for use with solid fuel appliances. 

DO NOT OVER-FIRE

 – it is possible to fire the 

stove beyond its design capacity. This could 
damage the stove so watch for signs of over-
firing.  If any part of the stove starts to glow 
red, the stove is in an over-fire situation and 
the controls should be adjusted accordingly. 
Never leave the stove unattended for long 
periods without first adjusting the controls to 
a safe setting. Careful air supply control 
should be exercised at all times. 

FUME EMISSION – 

properly installed and 

operated, this appliance will not emit fumes. 
Occasional fumes from de-ashing and 
refueling may occur. Persistent fume emission 
must not be tolerated.  

This appliance should not be operated with 
the doors open 

If fume emission does persist then the 
following action should be taken immediately 
– 

 

Open Doors and windows to ventilate 
room. 

 

Let the fire out, or eject and safely 
dispose of fuel from the appliance. 

 

Check for flue/chimney blockage and 
clean if required. 

 

Do not attempt to relight the fire until 
the cause has been identified and 
corrected. 

 

If necessary seek professional advice. 

ADVERSE WEATHER – 

In a small number of 

installations, occasional local weather 
conditions (e.g. wind from a particular 
direction) may cause downdraught in the flue 
and the stove to emit fumes. In these 
circumstances the stove should not be used. A 
professional flue installer will be able to 
advise on solutions to this problem (e.g. anti-
downdraught cowl). 

EXTRACTOR FANS – DO NOT FIT AN 
EXTRACTOR FAN IN THE SAME ROOM AS 
THIS APPLIANCE. 

IN THE EVENT OF A CHIMNEY FIRE -  

 

Raise the alarm  

 

Call the Fire Brigade 

 

Close appliance air controls 

 

Move furniture, ornaments etc away  

 

Place a fireguard in front of stove 

 

Check the chimney breast for signs of 
excessive heat. 
 

If the wall is becoming excessively hot, move 
furniture away. Ensure the Fire Brigade can 
gain access to your roof space in order to 
check for fire spread.

Содержание CVSDL04-FP3BLK

Страница 1: ...JINDLU04 Rev G 21 04 16 Wood Burning Inset Stove Installation and Operating Instructions CVSDL04 FP3BLK CVSDL04 FP4BLK CVSDL04FP3PWT CVSDL04 FP4PWT R4...

Страница 2: ...s Park Exeter United Kingdom EX1 3QS DSEN13229 Inset Wood Burning Stove Appliance Mass 70kg Efficiency 79 Nominal Heat Output 4 9kW Mean Co Emission 13 O2 0 09 Mean OGC Emission 13 O2 99 mg m3 n Mean...

Страница 3: ...ons scheme it is a legal requirement in the UK to notify your local building control body in advance of any work starting HEALTH AND SAFETY PRECAUTIONS Special care must be taken when installing the s...

Страница 4: ...stent fume emission must not be tolerated This appliance should not be operated with the doors open If fume emission does persist then the following action should be taken immediately Open Doors and w...

Страница 5: ...terials The dimensions of the opening should be at least those shown in the diagram Ensure there is a sufficient overlap where the convection chamber flange meets the face of the opening If not either...

Страница 6: ...the kit before proceeding HEARTH REQUIREMENTS A constructional hearth with a minimum thickness of 125mm should be provided The constructional hearth should be made of solid non combustible material an...

Страница 7: ...cordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS EN 1856 can be used These chimneys must be fitted in accordance with the manufacturer s ins...

Страница 8: ...xings and the flue outlet as well as protect the internal components from damage during the installation process 1 To open the stove door press on the door lever to release it from the latch Swing the...

Страница 9: ...s into the centre and remove them from the stove 5 Remove the three rear brick sections noting their positions and orientation 6 Lift up and remove the base brick 7 Remove the Air Valve Cassette by re...

Страница 10: ...ce 2 Drill a 6mm hole into the hearth in the centre of the base plate fixing hole Use the screw supplied to fix the stove in place Any voids around the stove must be In filled with vermiculite concret...

Страница 11: ...hen filled and sealed once the installation is complete Alternatively a connection can be made using a register plate although it will be necessary to allow access for fitting the flue pipe to the reg...

Страница 12: ...d it when in the closed position COMMISSIONING Upon completion of the installation allow a suitable period of time for any fire cement and mortar to dry out A small fire may then be lit and the instal...

Страница 13: ...or unseasoned wood will create tar deposits in the stove and chimney increase harmful emissions and will not produce a satisfactory heat output Do not burn waste mineral fuel or treated or painted woo...

Страница 14: ...he stove door Once the kindling is well alight open the door and build the fire by gradually adding slightly larger pieces of wood closing the door afterwards Once the fire is established close the Ig...

Страница 15: ...can be replaced with new available from your dealer Air Valve Cassette this should be removed and cleaned monthly to remove any ash that may be in the controls N B Make sure that controls are in the...

Страница 16: ...t may therefore be necessary to adjust the door catch to maintain the door seal To adjust the catch slacken the two set screws on the catch bar and adjust the position of the catch bar as necessary Ai...

Страница 17: ...JINDLU04 Rev G 21 04 16 Stove Spares BODY SPARES...

Страница 18: ...JINDLU04 Rev G 21 04 16 Stove Spares DOOR SPARES...

Страница 19: ...JINDLU04 Rev G 21 04 16 Stove Spares AIR VALVE CASSETTE SPARES...

Отзывы: